TP-LINK TL-SG3424P User Manual
Figure 13-11 Alarm Config
The following entries are displayed on this screen:
¾
Alarm Table
Select:
Select the desired entry for configuration.
Index:
Displays the index number of the entry.
Variable:
Select the alarm variables from the pull-down list.
Port:
Select the port on which the Alarm entry acts.
Sample Type:
Specify the sampling method for the selected variable and
comparing the value against the thresholds.
comparing the value against the thresholds.
z
Absolute: Compares the values directly with the thresholds
at the end of the sampling interval.
at the end of the sampling interval.
z
Delta: Subtracts the last sampled value from the current
value. The difference in the values is compared to the
threshold.
value. The difference in the values is compared to the
threshold.
Rising Threshold:
Enter the rising counter value that triggers the Rising Threshold
alarm.
alarm.
Rising Event:
Select the index of the corresponding event which will be
triggered if the sampled value is larger than the Rising
Threshold.
triggered if the sampled value is larger than the Rising
Threshold.
Falling Threshold:
Enter the falling counter value that triggers the Falling
Threshold alarm.
Threshold alarm.
Falling Event:
Select the index of the corresponding event which will be
triggered if the sampled value is lower than the Falling
Threshold.
triggered if the sampled value is lower than the Falling
Threshold.
Alarm Type:
Specify the type of the alarm.
z
All: The alarm event will be triggered either the sampled
value exceeds the Rising Threshold or is under the Falling
Threshold.
value exceeds the Rising Threshold or is under the Falling
Threshold.
z
Rising: When the sampled value exceeds the Rising
Threshold, an alarm event is triggered.
Threshold, an alarm event is triggered.
z
Falling: When the sampled value is under the Falling
Threshold, an alarm event is triggered.
Threshold, an alarm event is triggered.
193