Transcend Information TS2GSDG User Manual

Page of 7
T
T
T
S
S
S
1
1
1
G
G
G
~
~
~
2
2
2
G
G
G
S
S
S
D
D
D
G
G
G
 
 
 
                           
Secure Digital Card
 
 
Transcend Information Inc.
 
 
3
Bus Operating Conditions 
 
• General 
Parameter 
Symbol
Min. 
Max. 
Unit 
Remark 
Peak voltage on all lines 
 
-0.3 VDD+0.3
V   
All Inputs 
Input Leakage Current 
 
-10 10 µA 
 
All Outputs 
Output Leakage Current 
 
-10 10 µA 
 
 
• Power Supply Voltage 
Parameter 
Symbol
Min. 
Max. 
Unit 
Remark 
Supply voltage 
V
DD
2.0 3.6  V 
CMD0, 
15,55,ACMD41 
commands 
Supply voltage specified in OCR register 
 
2.7 
3.6 
Except CMD0, 15,55, 
ACMD41 commands 
Supply voltage differentials (V
SS1
, V
SS2
)  -0.3 
0.3 V 
 
Power up time 
 
 
250 
ms 
From 0v to V
DD
 Min. 
Note. The current consumption of any card during the power-up procedure must not exceed 10 mA. 
 
• 
Bus Signal Line Load 
The total capacitance C
L
 the CLK line of the SD Memory Card bus is the sum of the bus master capacitance C
HOST
, the bus 
capacitance C
BUS
 itself and the capacitance C
CARD
 of each card connected to this line: 
C
L
 = C
HOST
 + C
BUS
 + 
Ν*C
CARD
 
Where N is the number of connected cards. Requiring the sum of the host and bus capacitances not to exceed 30 pF for 
up to 10 cards, and 40 pF for up to 30 cards, the following values must not be exceeded: 
 
Parameter 
Symbol
Min. 
Max. 
Unit 
Remark 
Bus signal line capacitance 
C
L
 100 
pF 
f
PP
 
≤ 20 MHz, 7 cards 
Single card capacitance 
C
CARD
 10 
pF 
 
Maximum signal line inductance 
 
 
16 
nH 
f
PP
 
≤ 20 MHz 
Pull-up resistance inside card (pin1) 
R
DAT3
10 90 k
Ω 
May be used for card 
detection 
 
Note that the total capacitance of CMD and DAT lines will be consist of C
HOST
, C
BUS
 and one C
CARD
 only since they are 
connected separately to the SD Memory Card host. 
 
Parameter 
Symbol
Min. 
Max. 
Unit 
Remark 
Pull-up resistance 
R
CMD
, R
DAT
10 100 k
Ω 
To prevent bus floating 
Bus signal line capacitance 
C
L
 250 
pF 
f
PP
 
≤ 5 MHz, 21 cards