Transition Networks MIL-SM2401MAF User Manual

Page of 178
 
                                                                               
 
160
 
(High), 3 = L (Low). 
 
Power Limit Max (mW) (<15400): Set the power limit value. The maximum 
value must less 15400. 
 
Fault Status: the PD error status message. There are three error status and 
explain as following. 
  Null: It means there is no PD connected or the connected PD device status 
is normal. 
  Overload: It means the current is over the PD current classification limited   
(475mA @ 48V DC) that the situation happens over 50msec. 
 
Mode Status: the PD current operation mode status. 
  V  sample  or  I  sample:  It  means  "  Current  sample  or  Voltage  sample”.   
When  PD  is  detected  and  current  is  supplied,  the  POE  switch  will  keep 
detecting and sampling some current or voltage to ensure whether the PD 
still present on this port. It is an IEEE 802.3af operating procedure. 
  R detect: When the port doesn’t connect with any PD, the POE switch will 
poll each port and detects the resistor. 
 
Discovery R (ohms): display resistance value. 
 
Port Current (mA): display current value. 
 
Port Voltage (V): display voltage value. 
 
Port Power (W): display watt value. 
 
Class  Current  (mA):  display  power  class.  When  you  enable  the  “Bypass 
classification” function, the class value will not show in here. 
 
Determined  Class:  display  power  class.  When  you  enable  the  “Bypass 
classification” function, the class value will not show in here.