Transition Networks SISGM1040-244 User Manual

Page of 117
Transition Networks 
 
                                            SISGM1040-244 
 
24-Hour Technical Support: 1-800-260-1312                            International: 00-1-952-941-7600 
 
 
 
 
 
 
Tighten the wire-clamp screws for preventing the wires from loosing. 
 
Note 
The wire gauge for the terminal block should be in the range 
between 12~ 20 AWG. 
 
 
LED Indicators   
 
There are few LEDs display the power status and network status located on the front 
panel of 4 10/100/1000T + 4 SFP Industrial Switch, each of them has its own specific 
meaning as tabled below. 
 
LED 
Color 
Description 
On 
The industrial switch is the master of the X-ring 
group 
R-Master 
Green 
Off 
The industrial switch is not the master of the X-ring 
group 
On 
Power input 1 is active 
PWR1 
Green 
Off 
Power input 1 is inactive 
On 
Power input 2 is active 
PWR2 
Green 
Off 
Power input 2 is inactive 
On 
Power input 1 or 2 is inactive or port link down 
  (depends on Fault Relay Alarm configuration) 
P-Fail 
Red 
Off 
Power input 1 and 2 are both functional, or no power 
inputs