-24-
G0513X/G0514X/G0514X3 Extreme Series Bandsaw
Figure 20. Squaring table to blade.
5.  Adjust the positive stop bolt to the table and 
secure  it  by  tightening  the  hex  nut  against 
the trunnion bracket.
6.  Check the adjustment for accuracy once you 
have tightened the hex nut.
7.  Loosen the screw on the pointer, but do not 
remove it.
8.  Align the tip of the pointer with the 0˚ mark on 
the table tilt scale.
9.  Tighten the screw on the pointer so that the 
pointer is locked in place.
To set the positive stop:
1.  DISCONNECT BANDSAW FROM POWER!
2.  Adjust the blade tension until the mark on the 
blade tension scale is between 4 and 6.
3.  Loosen  the  hex  nut  that  locks  the  positive 
stop bolt in place.
4.  Raise the guide post and place a machinist’s 
square  on  the  table  next  to  the  side  of  the 
blade as illustrated in 
Figure 20. Adjust the 
table square with the blade, then secure with 
the table tilt knobs.
Figure 21. Dust hose attached to dust port.
Dust Collection
Recommended CFM at Each Dust Port:  400 
Do  not  confuse  this  CFM  recommendation  with 
the rating of the dust collector. To determine the 
CFM at the dust port, you must take into account 
many  variables,  including  the  CFM  rating  of  the 
dust  collector,  the  length  of  hose  between  the 
dust  collector  and  the  machine,  the  amount  of 
branches or wyes, and the amount of other open 
lines throughout the system. Explaining this cal-
culation is beyond the scope of this manual. If you 
are unsure of your system, consult an expert or 
purchase a good dust collection "how-to" book.
To connect a dust collection hose:
1.  Fit  a  4"  dust  hose  over  each  dust  port,  as 
shown in 
Figure 21, and secure in place with 
a hose clamp.
2.  Tug  each  hose  to  make  sure  it  does  not 
come  off. 
Note:  A  tight  fit  is  necessary  for 
proper performance.
DO  NOT  operate  this  bandsaw  without  an 
adequate  dust  collection  system.  This  saw 
creates  substantial  amounts  of  wood  dust 
while operating. Failure to use a dust collec-
tion system can result in short and long-term 
respiratory illness.
3.  Attach the dust hoses to a dust collector.