Allied Telesis X8106 User Manual

Page of 240
SwitchBlade x8106 Chassis Switch Installation Guide
185
2. Connect the other end of the cable to an RS-232 port on a terminal or 
personal computer with a terminal emulation program.
3. Configure the VT-100 terminal or terminal emulation program as 
follows:
Baud rate: 115,200 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow controller: None 
Note
The port settings are for a DEC VT100 or ANSI terminal, or an 
equivalent terminal emulator program. 
4. Press Enter. You are prompted for a user name and password.
5. Enter the default user name and password. They are “manager” and 
“friend” (without the quotes), respectively 
Note
User names and passwords are case sensitive. 
The local management session starts and the command line interface 
(CLI) prompt is displayed.
Entering the
AlliedWare Plus
Operating System
Commands
To confirm the operations of the chassis with the commands in the 
AlliedWare Plus Operating System, perform the following procedure:
1. Enter the SHOW VERSION command in the User Exec or Privileged 
Exec mode to display the software version number of the AlliedWare 
Plus Operating System on the controller card, as shown in Figure 135 
on page 186.