Chapter 9: Troubleshooting
202
Local (Out-of-Band) Management Session
If you are unable to establish a local (out-of-band) management session 
with the switch through the Console RS-232 port on the active master 
controller card, do the following:
Check to be sure that the RJ-45 serial management cable is 
securely connected to the Console RS-232 port on the active 
master controller card and the RS-232 port on the terminal or 
personal computer.
If the chassis has two controller cards, verify that the management 
cable is connected to the console port on the active master 
controller card by examining the M/S LEDs on the cards. The 
LEDs are solid green on the active master controller card and solid 
or flashing amber on the standby master controller card.
Check to be sure that the operating parameters on the terminal or 
the terminal emulation program, if you are using a personal 
computer, have been set correctly. The default settings for the RJ-
45 serial terminal port are located in “Using Local Management to 
Verify the Chassis” on page 184.
Check to be sure that the terminal emulator application is 
compatible with a VT-100 terminal.