JVC SR-9240EK User Manual

Page of 55
54
Time
During recording
During standby
1 field
5m sec
GND
Timelapse recording
Camera switching signal 
(open-collector output)
11-2  Rear Panel’s Input/Output
[CAM SW OUT] camera switching signal output
The CAM SW OUT terminal outputs a camera switching timing signal to the connected sequential switcher. The switching interval
can be set with the <CAM SW> on the VTR mode 1 setting screen.  The camera switching signal is output at ground level.
Camera
switching
signal output
timing
Terminals
Signal levels
Remarks
About 2 
seconds
Min. 400 ms
Min. 400 ms
Alarm 
Record mode
LV: 0 V
Max. 10 mA
LV: 0 V
HV: 5 V ~ 12 V
HV:12 V 
(output impedance: 4.7 kohms)
Record mode: 
repeat recording ON/auto rewind ON
Tape end
Manual 
operation
Warning
Warning reset
HV: 12 V 
(output impedance: 4.7 kohms)
Record mode: 
repeat recording OFF/auto rewind OFF
ALARM IN
Alarm signal input
ALARM REC OUT
Alarm recording 
mode signal output
TAPE END OUT
Tape end signal 
output
WARNING/REC 
OUT
Warning signal/Rec 
mode signal output
ALARM RST IN
Alarm signal reset 
input
Input at ground level
Min. 150 ms
LV: 0 V
CLOCK RESET IN
Clock reset input
Input at ground level
About 150 ms
LV: 0 V
CLOCK RESET 
OUT
Clock reset output
Output at ground level
Input at high level
Output at high level
Output at high level
Output at ground level
Other input/output terminal signal levels
11  APPENDIXES
With the <CAM SW>
function menu switch
set to "1 FIELD"