Martin Fireplaces SB5400SS User Manual

Page of 36
O
UTSIDE
  C
OMBUSTION
  A
IR
  P
RECAUTIONS
  & R
ECOMMENDATIONS
22
O
UTSIDE
 C
OMBUSTION
 A
IR
 R
ECOMMENDATIONS
  (
CONTINUED
)
1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly
should be avoided.  These conditions will increase the resistance to the free flow of air through the duct.
Refer to Figures 1, 23, and 24 for methods of installing the outside air for combustion assemblies.
2. The combustion air assembly should be located at an exterior location, which is not likely to be accidentally
blocked in any manner.  The assembly should be located above the snow line to prevent blockage by snow
accumulation.
3. The combustion air inlet assembly should never be mounted in a garage or storage area where combustible
fumes such as gasoline might be drawn into the fireplace.
4. Combustion air can be drawn form the crawl space under a house when an adequate supply of air is
provided by open ventilation.
5. Do not take combustion air from attic space or garage space.
OUTSIDE AIR CONTROL 
OUTSIDE AIR CONTROL 
LEVER (LIFT TO OPEN,
LEVER (LIFT TO OPEN,
PULL DOWN TO CLOSE)
PULL DOWN TO CLOSE)
COMBUSTION AIR ASSEMBLY 
COMBUSTION AIR ASSEMBLY 
    FOR MODEL NO. AK-4
    FOR MODEL NO. AK-4
SCREWS
SCREWS
6" DIA. HOLE FOR AK-4 
6" DIA. HOLE FOR AK-4 
 NAIL
 NAIL
HOLES
HOLES
F
IGURE
 24
53D9028. Rev 1 03/03