Regency E21-NG3 User Manual

Page of 36
21
Regency
®
 E21-3 Gas Fireplace Insert
Conversion Kit# 534-969 from NG to LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one LPG 
Conversion Kit and one DC
Sparker Kit.
LPG Conversion Kit Contains:
Qty. Part # 
Description
1  
904-163  Burner 
Orifi 
ce 
#54
1  
904-529  5/32" 
Allen 
Key
  918-590 
Label "Converted to  
  
 
LPG"
1  
908-528  Red 
"LPG" 
label
  910-037 
LP Injector (Pilot Orifi ce)
1  
910-233  Thermodisc 
Switch
1  
918-482  Instruction 
Sheet
DC Sparker Kit Contains:
Qty. Part # 
Description
1  
820-475  Bracket 
DC 
Sparker 
1  
820-476  Bracket 
DC 
Sparker
  904-153 
Washer #8 External Star 
1  
904-330  Nut 
8-32 
Hex
  904-531 
Bushing Split Plastic  
  
0.500 
in.
  904-543 
Screw 8-32 x 3/4 Pan 
  
Head
  904-553 
Screw #8 x 1/2 Type "B",  
  
Black 
Oxide
  910-073 
Spark Generator Battery  
  
Holder
  910-074 
Spark Generator Switch  
  
C/W 
Wire
1  
910-078  Battery 
Size 
AA 
  
Energizer 
En91
1  
910-199  Clip 
Wire 
Holder
  910-903 
Wire Fan To Power Cord 
   
Ground 30 in.
  
  904-781 
Velcro Hook, Black 
  
  904-782 
Velcro Hook, Black
Installation of LPG 
Conversion Kit:
1) 
Turn the unit off and allow it to cool to 
room temperature.
2) 
Shut off gas supply.
3) 
Unplug or disconnect power source to 
stove.
4) 
Remove glass front (see Door Glass 
Replacement section in the manual).
5) 
Remove logs and brick panels (if 
 installed).
6) 
Remove the Grate by removing the 2 
screws; one on each side of the grate.
7) 
Remove the Burner Tray by removing 1 
screw on each side of the tray, then slide 
the tray to the left and lift out.
9) 
Unscrew the pilot  orifi ce with the allen 
key (provided) and replace with the LP 
pilot orifi ce in the kit.
Burner
Orifi ce
Remove the 2 screws holding 
the grate in position.
Remove the 2 screws, 
push Burner Tray to the left, and lift off.
10)  Remove burner orifi ce with 1/2" 
wrench. Use another wrench to hold 
onto the elbow behind the offi ce 
Replace with the #54 orifi ce in the Kit.
11)  Turn control knob to the “OFF” 
position.
12)  Remove the black protection cap by 
hand from the high-low knob (Fig.1).
Fig. 1
13)  Insert a 5/32” or 4mm Allen wrench into 
the hexagonal key-way of the screw 
(Fig. 2), rotate it counter-clockwise 
until it is free and extract it.
Fig.2
8) 
Pull off the pilot cap to expose the pilot 
orifi ce.
INSTALLATION