Panasonic MA6Z718 User Manual

Page of 3
Schottky Barrier Diodes (SBD)
1
Publication date: April 2004
SKH00114BED
MA6Z718 
(MA6S718)
Silicon epitaxial planar type
For switching
■ Features
• Three isolated elements are contained in one package, allowing
high-density mounting
• Forward voltage V
F
 , optimum for low voltage rectification
• Optimum for high frequency rectification because of its short
reverse recovery time t
rr
■ Absolute Maximum Ratings  T
a
 
= 25°C
Parameter
Symbol
Rating
Unit
Reverse voltage
V
R
30
V
Maximum peak reverse voltage
V
RM
30
V
Peak forward current 
*
I
FM
150
mA
Forward current 
*
I
F
30
mA
Junction temperature
T
j
125
°C
Storage temperature
T
stg
−55 to +125
°C
Internal Connection
Marking Symbol: M2N
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Forward voltage
V
F1
I
F
 
= 1 mA
0.4
V
V
F2
I
F
 
= 30 mA
1.0
Reverse current
I
R
V
R
 
= 30 V
1
µA
Terminal capacitance
C
t
V
R
 
= 1 V, f = 1 MHz
1.5
pF
Reverse recovery time 
*
t
rr
I
F
 
= I
R
 
= 10 mA
1.0
ns
I
rr
 
= 1 mA, R
L
 
= 100 Ω
Detection efficiency
η
V
IN
 
= 3 V
(peak)
 , f 
= 30 MHz
65
%
R
L
 
= 3.9 kΩ, C
L
 
= 10 pF
■ Electrical Characteristics  T
a
 
= 25°C ± 3°C
1
2
3
6
5
4
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
R
s
 = 50 Ω
Wave Form Analyzer
(SAS-8130)
R
i
 = 50 Ω
t
p
 = 2 µs
t
r
 = 0.35 ns
δ = 0.05
I
F
 = 10 mA
I
R
 = 10 mA
R
L
 = 100 Ω
10%
Input Pulse
Output Pulse
I
rr
 = 1 mA
t
r
t
p
t
rr
V
R
I
F
t
t
A
Unit: mm
1: Anode 1
4: Cathode 3
2: Anode 2
5: Cathode 2
3: Anode 3
6: Cathode 1
EIAJ: SC-88
SMini6-F1 Package
(0.65)(0.65)
2.0
±0.1
0.7
±0.1
1.25
±
0.1
2.1
±
0.1
0.16
+0.10
–0.06
1
2
3
6
5
4
0.2
±0.05
(0.425)
(0.15)
0 to 0.1
Note) *: Value for single diode
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body
and the leakage of current from the operating equipment.
3. Absolute frequency of input and output is 2 GHz.
4. *: t
rr
 measurement circuit
Note) The part number in the parenthesis shows conventional part number.
This product complies with the RoHS Directive (EU 2002/95/EC).