Installation
 
Unpack and inspect all parts carefully. The following parts are supplied:
1
CM6800E Switcher/Controller 
4
10-32 x .750-inch pan head screws
4
.500” OD nylon washers
1
Power cord
4
6-foot (1.8 m) straight data cables with RJ-45 connectors
1
6-foot (1.8 m) reversed data cable with RJ-45 connectors
4
RJ-45 wall block terminals 
 
NOTE:  
 
There are no user-serviceable parts inside this unit. Only authorized service personnel may open the unit.
 
MOUNTING
 
1. Select a suitable location for the CM6800E. It occupies 5.25 inches (13.34 cm) of vertical space, or three rack units (RUs), in a universal 
mount. The CM6800E must be within 6 feet (1.8 m) of a suitable electrical outlet. 
 
Follow proper installation practices and leave 1 RU above and below the CM6800E for ventilation. If installing a 96 x 16 
system, in one vertical rack, leave 1 RU between each CM6800E-48X8 unit for ventilation.
Do not connect the power until the installation is complete. Refer to the 
 
System Start-Up
 
 section.
 
2. The CM6800E is shipped with the rack ears installed at the front. Reposition or remove ears as needed for your application. 
 
Figure 4.  
 
Installing Rack Ears
 
3. Use supplied pan head screws and washers to mount the CM6800E in a standard 19-inch (48.26 cm) equipment rack or wood or sheet 
metal screws to mount against a flat surface, according to your installation requirements.
 
Figure 5.  
 
Mounting the CM6800E Matrix Switcher/Controller
POSITION BRACKETS FOR
RACK MOUNTING (FRONT)
POSITION BRACKETS FOR
FLUSH MOUNTING
(WALL AND TABLE TOP)
POSITION BRACKETS FOR
RACK MOUNTING (REAR)
NOTE: EACH CM6800 COMES
WITH 2 RACK EARS
POSITION BRACKETS FOR
UNDER-TABLE MOUNTING