Pelco C1528M-F User Manual

Page of 106
 
18
C1528M-F (6/05)
 
ALARMS
 
The CM6800E provides numerous alarm handling options. Refer to the 
 
Programming 
 
section for a detailed description.
1. Connect wires from the sensors to the respective alarm input points on the connectors at the back of the CM6800E. Each sensor requires 
two wires – one wire to the alarm input terminal and a return wire to one of the ground terminals on the connector. The CM6800E supports 
eight internal alarms.
Alarm sensors can be either N.O. (normally open) or N.C. (normally closed) contacts. The CM6800E is set to N.O. as a factory default.
2. If your system requires more than eight alarms, connect an ALM2064 unit to the system. Refer to the 
 
M Devices
 
 section.
 
96 x 16 System Alarm Capacity
 
Figure 11.  
 
Connecting Alarms 
 
Main unit:
Alarms 1-8
Expansion unit:
Alarms 9-16