SEQUENCE:
Select the sequence number you want to program.
STP:
Each sequence can include up to 72 steps. For each step select entries for the following fields as necessary:
CAM:
Enter the desired camera number (logical number).
DWL:
Enter the dwell time (01-99 seconds).
CMD and ##:
Select a command; if you select a pattern or a preset enter a valid pattern or preset number.
OPTIONS:
PRES = preset 
PATT = pattern
RSCN = random scan 
FSCN = frame scan
SSCN =  stop scan
AUX and ##:
Select an auxiliary to be activated.
Global = internal and external auxiliaries.
OPTIONS:
GON = turn global auxiliary on
GOFF = turn global auxiliary off
CON = turn camera auxiliary on
COFF = turn camera auxiliary off
NOTE:  Activate the auxiliaries on the rear panel of the CM6800E by selecting global auxiliary numbers 1, 
2, or 3 (in a 96 x 16 system the expansion unit auxiliaries are activated by global auxiliary numbers 4, 5, 
and 6). The remaining global auxiliary numbers control REL2064 Relay Interface Unit auxiliaries.