AMD Opteron™ Server 2000 MHz, Dual-Processor, WOF OSA246BLWOF Data Sheet
![AMD](https://files.manualsbrain.com/attachments/812c0ad06c29fa7e95b1abe2111a1edaa280e91d/common/fit/150/50/1bf990368109a76ea6bd2d8d055ff8d6014a81121adff709966c75a2bfec/brand_logo.png)
Product codes
OSA246BLWOF
PID: 30417 Rev. 3.11 - May 2006
AMD Opteron™ Processor Power and Thermal Data Sheet
11
AMD Opteron™ Processor
Note: The thermal profile is used to define the relationship between Tcase max and device-
specific Thermal Design Power for Rev. E and later processors with “Variable” indicated
by the Case Temperature OPN character.
by the Case Temperature OPN character.
The rmal Profile
D
E
F
The rmal Re sis tance
(cas e to ambie nt)
(cas e to ambie nt)
0.34°C/W
0.95°C/W
0.25°C/W
Local Ambie nt
Te mpe rature
Te mpe rature
42°C
42°C
42°C
Tcase Max
Powe r
(The rmal Profile D)
Powe r
(The rmal Profile E)
Powe r
(The rmal Profile F)
49°C
20.6 W
7.4 W
28.0 W
51°C
26.5 W
9.5 W
36.0 W
53°C
32.4 W
11.6 W
44.0 W
55°C
38.2 W
13.7 W
52.0 W
57°C
44.1 W
15.8 W
60.0 W
59°C
50.0 W
17.9 W
68.0 W
61°C
55.9 W
20.0 W
76.0 W
63°C
61.8 W
22.1 W
84.0 W
65°C
67.0 W
24.2 W
92.0 W
67°C
N/A
26.3 W
95.0 W
69°C
N/A
28.4 W
N/A
71°C
N/A
30.0 W
N/A
The rmal Profile
G
H
I
The rmal Re s is tance
(cas e to ambie nt)
(cas e to ambie nt)
0.51°C/W
0.22°C/W
0.20°C/W
Local Ambie nt
Te mpe rature
Te mpe rature
42°C
42°C
42°C
Tcas e Max
Powe r
(The rmal Profile G)
Powe r
(The rmal Profile H)
Powe r
(The rmal Profile I)
49°C
13.7 W
31.8 W
35.0 W
51°C
17.6 W
40.9 W
45.0 W
53°C
21.6 W
50.0 W
55.0 W
55°C
25.5 W
59.1 W
65.0 W
57°C
29.4 W
68.2 W
75.0 W
59°C
33.3 W
77.3 W
85.0 W
61°C
37.3 W
86.4 W
95.0 W
63°C
41.2 W
95.5 W
105.0 W
65°C
45.1 W
104.0 W
110.0 W
67°C
49.0 W
N/A
N/A
69°C
52.9 W
N/A
N/A
71°C
55.0 W
N/A
N/A