MEAN WELL DR-75-48 DIN-Rail Power Supply Unit, 75W 48V DC DR-75-48 Leaflet

Product codes
DR-75-48
Page of 2
SPECIFICATION
DR-75-12
DR-75-24
DR-75-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
12V
24V
48V
6.3A
3.2A
1.6A
0 ~ 6.3A
0 ~ 3.2A
0 ~ 1.6A
76W
76.8W
76.8W
100mVp-p
150mVp-p
240mVp-p
2.0%
1.0%
1.0%
12 ~ 14V
24 ~ 28V
48 ~ 53V
0.5%
0.5%
0.5%
1.0%
1.0%
1.0%
85 ~ 264VAC
120 ~ 370VDC
47 ~ 63Hz
76%
80%
81%
1.6A/115V
0.96A/230V
COLD START 20A/115VAC
40A/230VAC
<1mA / 240VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
15 ~ 16.5V
29 ~ 34V
58 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
85
5
(TSW1) detect on heat sink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
UL508, TUV EN60950-1 approved
Compliance to EN55011,EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
-10 ~ +60
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/
(0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
123.1K hrs min.
MIL-HDBK-217F (25
)
55.5*125.2*100mm (W*H*D)
0.6Kg; 20pcs/13Kg/1.29CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:DR-75-SPEC 2011-06-17
1000ms, 60ms/230VAC
1800ms, 60ms/115VAC at full load
60ms/230VAC
12ms/115VAC at full load
75W Single Output Industrial DIN Rail Power Supply
D R - 7 5
s e r i e s
Universal AC input / Full range
Protections:Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508(industrial control equipment)approved
LED indicator for power on
100% full load burn-in test
Fix switching frequency at 50KHz
3 years warranty
Features :
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 4)
EMC IMMUNITY
EMC EMISSION