Panasonic PT-VW431D User Manual

Page of 13
S
P
E
C
F
I
L
E
PT-VW431D
LCD  Projector
As  of  September 2012
SFL12M015
1 0 / 1 3
Serial  connector
The  serial  connector  complies  with  RS-232C.  To  control  the  projector  from  a  personal  computer,  com-
mands  must  be  input  through  communication  software,  based  on  the  format  and  satisfying  the  commu-
nication  conditions  shown  below.
Basic  format
Transmission  from  the  computer  begins  with  STX,  then  command,  parameter,  and  ETX  are  sent  in  this
order.  Add  parameters  according  to  the  details  of  control.
Communication  conditions  (factory  setting)
Pin  assignments  and  signal  names
6
1
5
9
D-sub  9-pin  (female)
Serial  input
Description
NC
Send  data
Receive  data
NC
Ground
Signal  name
TXD
RXD
GND
No.
1
2
3
4
5
Description
NC
Connected  internally
Connected  internally
NC
Signal  name
CTS
RTS
No.
6
7
8
9
CAUTION
• It  may  not  be  possible  to  send  or  receive  commands  for  about  10  to  60  seconds  when  the  lamp  is  first  turned  on.  If  this  occurs,  wait  for  60  sec-
onds,  then  try  sending  or  receiving  again.
• When  sending  multiple  commands,  be  sure  to  wait  for  at  least  0.5  second  after  receiving  a  response  from  the  projector  before  sending  the  next
command.
• Additional  time  is  sometimes  required  for  response  due  to  processing  inside  the  projector.  Set  the  time-out  period  for  command  response  to  10
seconds  or  more.
Start
(1 byte)
End
(1 byte)
Colon
(1 byte)
Parameters 
(undefined length)
Command
(3 bytes)
STX
ETX
C1
P1 P2 ... Pn
C2 C3
:
Signal  level
Synchronization  method
Baud  rate
Parity
RS-232C-compliant
Start-stop  synchronization
9,600  bps
None
NOTE:  When  sending  commands  without  parameters,  a  colon  (:)  is  not  necessary.
Basic  format  with  sub-commands
Same as the basic format without sub-commands
Parameters (6 bytes): 
“+” or “-” sign (1 byte) with setting/adjusting value (5 bytes)
Sub-command
(5 bytes)
Operation (1 byte): 
“=” (Sets the value designated by the parameters)
S1
P1 P2 P3 P4 P5 P6
S2 S3 S4 S5
E
STX
ETX
C1 C2 C3
:
Character  length
Stop  bit
X  parameter
S  parameter
8  bits
1  bit
None
None