10. Installation 
Instruction 
10.1  Select the Best Location 
10.1.1 Indoor 
Unit 
x  There should not be any heat source or steam near the 
unit.
x  There should not be any obstacles blocking the air 
circulation. 
x  A place where air circulation in the room is good. 
x  A place where drainage can be easily done. 
x  A place where noise prevention is taken into consideration. 
x  Do not install the unit near the door way.  
x  Ensure the spaces indicated by arrows from the wall, ceiling, 
fence or other obstacles. 
x  Recommended installation height for indoor unit shall be at 
least 2.5m. 
10.1.2 Outdoor 
Unit 
x  If an awning is built over the unit to prevent direct sunlight or 
rain, be careful that heat radiation from the condenser is not 
obstructed. 
x  There should not be any animal or plant which could be 
affected by hot air discharged. 
x  Keep the spaces indicated by arrows from wall, ceiling, 
fence or other obstacles. 
x  Do not place any obstacles which may cause a short circuit 
of the discharged air. 
x  If piping length is over the rated length, additional refrigerant 
should be added as shown in the table below: 
Example: If the unit is installed at a 10m distance, the quantity 
of additional refrigerant should be 50 g. 
…… (10-7.5) m x 20g/m = 50 g 
Piping size 
Model 
Gas Liquid 
Rated
Length 
(m)
Max 
Elevati
on (m) 
Min
Piping 
Length 
(m)
Max 
Piping 
Length 
(m)
Additional 
Refrigera
nt (g/m) 
RE9JKX 3/8” 
1/4"  7.5 
15 
20 
RE12JKX 3/8” 1/4” 
7.5 
15 
20 
RE15JKX 1/2” 1/4” 
7.5 
15 
20 
11.1.3 Indoor/Outdoor Unit
*This illustration is for explanation purposes only. 
 The indoor unit will actually face a different way.