11. Installation
Information
11.1 Check Points
11.2 The Shapes of the 3-Way Valve Caps of the Outdoor Unit Have Changed.
• Accompanying the changes in the shapes of the 3-way valve caps, the tightening method has also been
changed.
• Firmly tighten the 3-way valve caps by hand and then tighten them up by another 30 degrees or so (one-twelfth
of a full turn) using a spanner or adjustable spanner.
Panasoni c
Panasoni c
Allowable
elevation:
elevation:
10m max
.
The allowable
elevation between
each of the indoor
units and between
the indoor and
outdoor units.
elevation between
each of the indoor
units and between
the indoor and
outdoor units.
1.5mm
2
flexible cord x 4 core
(poluchloroprene sheathed)
(Not included in the unit)
Outdoor unit power supply:
Single-phase 230V, 50Hz
Single-phase 230V, 50Hz
20A switch
(circuit breaker)
(Not included in the unit)
(circuit breaker)
(Not included in the unit)
1.5 mm2 or more x 3 core
(Not included in the unit)
(Not included in the unit)
Drain work
Drain elbow
(Inner diameter: 16mm) provided
(Inner diameter: 16mm) provided
Outdoor wiring work
Unit B
Unit A
Applicable connecting tube kit:
CZ-3F type
CZ-3F type
Total maximum pipe length: 30 m
Air purging: Air purging by vacuum pump.
Unit A Maximum pipe length: 20 m
Unit B Maximum pipe length: 20 m
Indoor/outdoor unit
connection cables
connection cables
(Not included in the unit)
Grounding work
Caution:
Do not use all your strength to tighten up
the caps. Doing so may break the caps.
the caps. Doing so may break the caps.
After having firmly tightened the caps by hand,
tighten them up further using a
spanner or adjustable spanner.
spanner or adjustable spanner.