Cooling capacity
Nominal (Min - Max)
kW
2,50 (0,90-3,00)
3,30 (0,90-3,90)
5,00 (0,90-5,30)
Nominal (Min - Max)
kCal/h
2.150 (770-2.580)
2.838 (770-3350)
4.300 (770-4558)
EER
1)
Nominal (Min - Max) Energy Saving 3,28 (4,73 -3,00)
A
3,23 A (4,5-3,00)
A
3,01 (4,16-2,71)
B
Power input Cooling
Nominal (Min - Max)
kW
0,76 (0,19-1,00)
1,02 (0,20-1,3)
1,66 (0,24-1,95)
Heating capacity
Nominal (Min - Max)
kW
3,20 (0,90-4,20)
4,00 (0,90-5,00)
5,50 (0,90-6,80)
Nominal (Min - Max)
kCal/h
2.750 (770-3.612)
3.404 (770-4.300)
4.730 (770-5848)
Heating capacity at +2°C
Nominal
kW
3,00
3,60
4,95
COP
1)
Nominal (Min - Max) Energy Saving 3,63 (4,73-3,50)
A
3,61 (4,50-3,52)
A
3,40 (4,28-2,89)
B
Power input Heating
Nominal (Min - Max)
kW
0,88 (0,19-1,20)
1,10 (0,20-1,42)
1,61(0,21-2,35)
Annual Energy Consumption
2)
kWh
380
510
830
iNdOOR UNit
Power source
V
230 (Via outdoor)
230 (Via outdoor)
230 (Via outdoor)
Connection
mm²
4 x 2,5
4 x 2,5
4 x 2,5
Current (Nominal)
Cooling / Heating
A
3,6 / 4,1
4,9 / 5,2
7,9 / 7,7
Max. current
A
5,80
6,90
10,5
Air Volume
Cooling / Heating
m³/h
750 / 780
810 / 834
876 / 918
Moisture removal volume
l/h
1,4
1,9
2,8
Sound pressure Level
3)
Cooling (Hi / Lo / S-Lo) dB(A)
40 / 27 / 22
42 / 30 / 22
46 / 31 / 29
Heating (Hi / Lo / S-Lo) dB(A)
40 / 27 / 23
42 / 33 / 25
46 / 30 / 27
Sound power Level
Cooling / Heating (Hi) dB
56 / 56
58 / 58
62 / 62
Dimensions
H x W x D
mm
283 x 803 x 214
283 x 803 x 214
283 x 803 x 214
Net weight
kg
8
8
7,5
OUtdOOR UNit
Air Volume
Cooling / Heating
m³/h
1.980 / 1.980
2.070 / 2.070
2.160 / 2.160
Sound pressure Level
3)
Cooling / Heating (Hi) dB(A)
47 / 48
48 / 50
50 / 52
Sound power Level
Cooling / Heating (Hi) dB
63 / 64
64 / 66
66 / 68
Dimensions
4)
H x W x D
mm
540 x 780 x 289
540 x 780 x 289
540 x 780 x 289
Net weight
kg
22
26,5
31,5
Piping connections
Liquid pipe
inch (mm)
1/4" (6,35)
1/4" (6,35)
1/4" (6,35)
Gas pipe
inch (mm)
3/8" (9,52)
3/8" (9,52)
1/2" (12,70)
Refrigerant Loading
R410A
kg
0,78
0,880
1,15
Elevation difference (in/out)
5)
Max
m
5
5
5
Piping length
Min / Max
m
3 / 15
3 / 15
3 / 15
Piping length without refrigerant
increase
Max
m
7,5
7,5
7,5
Additional gas
g/m
20
20
20
Operating range
3)
Cooling Min / Max
°C
+5 / +43
+5 / +43
+5 / +43
Heating Min / Max
°C
-5 / +24
-5 / +24
-5 / +24
CU-YE9MKE
CU-YE12MKE
CU-YE12MKE
CU-Y E18MKE
Kit-YE9-MKE // Kit-YE12-MKE //
Kit-YE18-MKE
Kit-YE18-MKE
HEALtHY AiR
· Odour-removing function
· Anti-mould filter
ENERGY, EFFiCiENCY ANd ECOLOGY
ENERGY, EFFiCiENCY ANd ECOLOGY
· Inverter system
· R410A refrigerant gas
COMFORt
COMFORt
· Super Quiet mode. Only 22 dB(A)
· Powerful mode
EASE OF USE
EASE OF USE
· 12-hr timer
· User friendly infrared remote control
EASY iNStALLAtiON ANd MAiNtENANCE
EASY iNStALLAtiON ANd MAiNtENANCE
· Maximum connection distance 15 m
· Removable, washable panel
ECoNomICAL, ENVIRoNmENT-FRIENDLY
oPERATIoN WITH HIGH CoP
(CoEFFICIENCY oF PERFoRmANCE)
oPERATIoN WITH HIGH CoP
(CoEFFICIENCY oF PERFoRmANCE)
Original Panasonic inverter technology and a high-
performance compressor provide top-class operating
efficiency. This lets you enjoy lower electricity bills while
contributing to environmental protection.
tECHNiCAL FOCUS
· QUIETER INDOOR UNITS
· HIGH ENERGy SAVINGS
· 12-HR REMOTE CONTROL TIMER
· LONG CONNECTION DISTANCE
WALL moUNTED // INVERTER
YE INVERTER moDELS ARE PoWERFUL AND EFFICIENT.
egge
associats
relaxing
breeze
effect
SOFT BREEZE
A
class
energy
saving
silent
air
22 dB
SUPER QUIET
INVERTER SySTEM
The Inverter range provides greater efficiency, more
comfort and less noise than classic air conditioners.
The Inverter system provides more precise temperature
control, and keeps the ambient temperature constant
with lower energy consumption and a significant
reduction in noise and vibration levels.
The Inverter range provides greater efficiency, more
comfort and less noise than classic air conditioners.
The Inverter system provides more precise temperature
control, and keeps the ambient temperature constant
with lower energy consumption and a significant
reduction in noise and vibration levels.
SOFT DRy OPERATION MODE
The soft dry mode eliminates excess moisture with a
soft breeze and provides a sense of wellbeing without
much change in temperature.
The soft dry mode eliminates excess moisture with a
soft breeze and provides a sense of wellbeing without
much change in temperature.
SUPER QUIET MODE
The indoor unit emits an almost
imperceptible 22 dB.
The indoor unit emits an almost
imperceptible 22 dB.
1) EER and COP classification is at 230V in accordance with EU directive 2002/31/EC.
2) The annual consumption is calculated by multiplying the input power at 230V by an
2) The annual consumption is calculated by multiplying the input power at 230V by an
avarage of 500 hours per year in cooling mode.
3) The Sound pressure level of the units shows the value measured of a position 1
meter in front of the main body and 1,5 from the ground. The sound pressure is
measured in accordance with Eurovent 6/C/006-97 specification.
measured in accordance with Eurovent 6/C/006-97 specification.
4) Add 70mm for piping port.
5) When installing the outdoor unit at a higher position than the indoor unit.
5) When installing the outdoor unit at a higher position than the indoor unit.
DB : Dry buld; WB : Wet buld
These indoor/outdoor units are not suitable for Nordic countries No warranty can be
applied if installed in Nordic countries
These indoor/outdoor units are not suitable for Nordic countries No warranty can be
applied if installed in Nordic countries
GLOBAL
REMARKS
REMARKS
Rating conditions
Cooling
Heating
Inside air temperature 27ºC DB / 19ºC WB 20ºC DB
Outside air temperature 35ºC DB / 24ºC WB 7ºC DB / 6ºC WB
Outside air temperature 35ºC DB / 24ºC WB 7ºC DB / 6ºC WB
Contact details:
E-mail: paul.taylor@eu.panasonic.com
Telephone: 01344 853182
www.panasonic.co.uk/aircon
E-mail: paul.taylor@eu.panasonic.com
Telephone: 01344 853182
www.panasonic.co.uk/aircon
Address: Panasonic Air Conditioning
Panasonic House
Willoughby Road
Bracknell
Berkshire
RG12 8FP
Panasonic House
Willoughby Road
Bracknell
Berkshire
RG12 8FP
to find out how Panasonic cares for you,
log on to: www.panasonic.co.uk/aircon
due
to
the
ongoing
inno
vation
of
our
pr
oducts,
the
specif
ications
of
this
catalogue
ar
e
valid
barring
typogr
aphic
err
or
s,
and
ma
y be
subject
to
minor
modif
ications
by
the
manufactur
er
without
prior
warning
in
or
der
to
impr
ov
e
the
pr
oduct.
the
total
or
partial
repr
oduction
of
this
catalogue
is
pr
ohibited
without
the
expr
ess
authorisation
of
Panasonic
UK
Ltd.
1kW
3.63 kW
1kW
1kW
INPUT
INPUT
oUTPUT
oUTPUT
ELECTRICAL HEATERS
PANASONIC’S HEAT PUMP
yE9MKE
Specifications subject to change without notice