Infortrend A24F-R2224 4U 24-Bay Rackmount A24F-R2224-15 User Manual

Product codes
A24F-R2224-15
Page of 4
w w w . i n f o r t r e n d . c o m
S P E C I F I C A T I O N S
Availability
Reliable Storage Networking Solution Provider
www.infortrend.com
www.infortrend.com
Serviceability
S p e c i f i c a t i o n s
Reliability
Subsystem Characteristics
.  
.  
.  Redundant RAID controllers
.  
.  BBUs per controller                           
.  
.  Serial 
.  
.  
Drive Interface
.  
.  
.  
.  S
.  
.  
.  
.  
.  
.  
.  
.  
600MHz RISC CPU, 512KB L2 cache
ASIC266 RAID engine                       
DDR cache memory                          512MB 
1
LCD keypad panel 
COM ports per controller         2
Ethernet ports per controller              1
Diagnostic LEDs on all FRUs
Number of disk trays                        
  
24
Serial ATA II/I drive support
Host Interface
2Gbps SFP ports                                8
ingle channel bandwidth                 200MBps
Tag command queuing
Multiple target IDs 
RAID Configurations
RAID levels 0, 1(0+1), 3, 5, 6, 10, 30, 50, 60, 
   JBOD
Max. 32 logical drives                       
Max. 1024 LUNs                                
Multiple array configurations         
Automatic background rebuild      
Intelligent drive handling                 
H i g h l i g h t s
IOSmart
DrvSmart
SysSmart
Infortrend Smart Technologies
High Availability
Redundant, and hot-swappable FRUs  
System self-diagnostics             
 battery backup module
UPS support
Management Software
RAIDWatch Manager software 
Terminal via RS-232C            
Telnet over Ethernet              
LCD keypad panel                
Event notification methods: 
   Email                          
   Fax                              
   LAN broadcast           
   SNMP traps      
   Cell phone message                        SMS
   Instant messages                     MSN/ICQ
OS Support
Microsoft Windows NT             
Microsoft Windows 2000 Server  
Microsoft Windows 2003 Server   
Sun Solaris ver. 8/9                       
Red Hat Linux ver. 8/9, Enterprise ver. 3                           
SUSE Linux ver. 8/9     
.  
.  
.  Dedicated and Global hot spare 
.  Li-ION
.  
.  
.  
.  
.  
.  
.  
.  
.  
.  
.  
.  
Requirements
.  Input Voltage: 
   90AC at 8A;264VAC at 4A with PFC        
   (auto-switching)
.  DC Output: 
   12V-24A; 5V-36A; 3.3V-20A
.  Relative Humidity: 
   5% to 95% non-condensing
.  Operating Temperature: 
O
O
   0 C to 40 C
Dimensions
.  4U, 19-inch rackmount chassis
.  Chassis with handles:  
   447(W) x 174.4(H) x 514(D) mm 
   (17.6 x 6.86 x 20.2 inches)
.  Chassis without handles:   
   482(W) x 174.4(H) x 498(D) mm 
   (18.9 x 6.86 x 19.6 inches)
Based on a proven architecture designed 
for continuous operation with heavy 
access loads, the EonStor A24F-R2224 is 
ideal for environments from SAN-attached 
storage to performance-intensive 
applications operating within an open-
system and multi-path framework.   
This SAN-ready subsystem meets the 
demands for enterprise-class storage in 
terms of its reliable firmware, ease of 
management, fault-proof hardware, and 
on-the-fly scalability.  
The EonStor A24F is powered by field-proven 
technologies that ensure data protection and 
performance to meet various storage needs.  Data is 
secured by sophisticated, redundant components and 
advanced firmware developed through a decade of 
experience in RAID technology.  In addition to the 
choice of RAID levels, 0, 1(0+1), 3, 5, 6, 10, 30, 50 and 
60, the subsystem protects your data with various high-
availability algorithms ranging from predictive checking 
and self-healing rebuilds to system self-diagnostics.   
To ensure a high level of availability, critical 
components such as disk drives, power supplies, 
and cooling fans are all redundant and hot-swappable.  
Modules are integrated with the passive backplane via 
board-to-board connectors to eliminate points of failure.  
Assisted by GUI management software, system 
administrators can constantly monitor the operating 
status of all components through a console locally or 
remotely situated.  The subsystem guarantees data 
integrity with selected, high MTBF components; a 
modular, fault-tolerant design; and a complete set of 
environmental monitoring and fault protection 
capabilities built in the firmware. 
All critical modules are housed in separate, easily 
retrievable canisters. In the event of component failure, 
a hard disk drive, power supply, battery module, RAID 
controller, or cooling fan can be replaced within 
seconds.  The modules are closely monitored using 
self-diagnostic features and the help of runtime 
utilities such as RAIDWatch.  Spring screws, securing 
latches, and key-locks all provide easier access to the 
modules.  
A variety of configuration and monitoring methods are 
available, either locally via the LCD keypad panel and 
the text-mode RS-232C terminal, or remotely through 
the Java-based GUI manager.  All faulty conditions, 
including RAID configuration events, module failure, 
voltage and temperature readings, are instantly 
reported.  A system administrator can select from the 
following notification methods to receive reports when 
away from the installation site: LAN broadcast, SNMP 
traps, email, fax, SMS, ICQ, and MSN Messenger.  Even 
the notification utility can be installed redundantly on 
two different machines to avoid the chance of blind time.    
In addition to RAID protection against drive failure, the 
subsystem has ingenious means to deal with other 
challenges that may jeopardize data integrity.  For 
example, hard disks wear down over time and drives 
may arrive from the manufacturer with inherent defects.  
Media Scan and Task Scheduler are among the DrvSmart 
utilities designed to detect and mend these problems.  
The subsystem is also equipped with error containment 
algorithms, known as the SysSmart functions.  If a 
critical component fails, e.g., a battery module, the 
subsystem automatically disables write-back caching 
and assumes the conservative write-through mode. 
If the fault condition persists for an extended period of 
time, the subsystem enters an idle state.  All of these 
precautions help ensure safe operation and data 
integrity.  
Derived from more than ten years of experience in RAID 
storage design, Infortrend's firmware features extremely 
compact protocol and rich varieties of algorithms to deal 
with the stringent requirements of storage applications.  
The technologies enhance I/O processing, drive 
handling, and system management.     
The IOSmart technologies consist of specific functions 
and configuration options that control various I/O 
characteristics in order to meet the rapidly increasing 
requirements of today's applications.  These functions 
include adaptable stripe size; write policy; optimizations 
modes; Guaranteed Latency I/O; and automatically 
adjusted, multi-threaded, predictive read-ahead, 
sorted, or group writes.  
DrvSmart is comprised of fault-preventive algorithms 
that ensure data integrity when hard drive imperfections 
occur.  These mechanisms correct minor defects, 
increase reaction time, allow more time to prepare a 
rebuild, and help minimize performance impact.  
DrvSmart functions include Media Scan and Task 
Scheduler, hot-spare, drive roaming, SMART and manual 
cloning options, and more.  
SysSmart combines enclosure monitoring and firmware 
management capabilities designed to minimize the 
chance of downtime caused by hardware failures.  With 
SysSmart, Infortrend's subsystems are smartly managed 
and guarded against extreme operating conditions.  
SysSmart functions include the event-triggered, 
adaptive write policy, auto-shutdown, dual-speed fan 
control, and the various monitoring utilities and 
approaches included in the powerful RAIDWatch Manager 
software.  
. Market leading I/O performance
       - Sustained RAID5 Read/Write: 770/460 (MB/sec)
. Ultra-high-density, 4U-profile, 24-bay enclosure
. Dual Active redundant controller
. Support RAID Level 0, 1(0+1), 3, 5, 6, 10, 30, 50, 60, 
  NRAID, JBOD
. Separate Host I/O board design
. Max. Connections for 8 host servers
. Four (4) FC-2G host channels
. Up to 12TB of storage capacity
. Support up to 2GB DDR RAM module
. Hot-swappable battery backup unit (BBU)
. Designed for SATA-II disk drives
. Ease of maintenance with host-swappable FRUs
. External UPS support