Cisco Catalyst 3850 WS-C3850-48P-E Data Sheet

Product codes
WS-C3850-48P-E
Page of 28
 
 
© 2013 Cisco and/or its affiliates. This document is Cisco Public Information. 
Page 22 of 28 
Power Supply Specifications 
Table 11 lists the power specifications for the Cisco Catalyst 3850 Series based on the kind of power supply used. 
Table 11. 
Power Specifications for Cisco Catalyst 3850 Series 
Description 
Specification 
 
PWR-C1-1100WAC 
PWR-C1-715WAC 
PWR-C1-350WAC 
PWR-C1-440WDC 
Power supply rated maximum 
1100W 
715W 
350W 
440W 
Total output BTU (Note: 1000 
BTU/hr = 293W) 
3793 BTU/hr, 1100W 
2465 BTU/hr, 715W 
1207BTU/hr, 350W 
1517BTU/hr, 440W 
Input-voltage range and 
frequency 
115-240VAC, 
50-60 Hz 
100-240VAC, 
50-60 Hz 
100-240VAC, 
50-60 Hz 
-36VDC to -72VDC 
Input current 
12-6A 
10-5A 
4-2A 
<8A@-72VDC 
<16A@-36VDC 
Output ratings 
-56V@19.64A 
-56V@12.8A 
-56V@6.25A 
-56V@7.86A 
Output holdup time 
10 ms minimum @ 
102.5VAC 
16.7 ms minimum @ 
100VAC 
16.7 ms minimum @ 
100VAC 
> 2ms@-48VDC 
Power-supply input receptacles 
IEC 320-C16 
(IEC60320-C16) 
IEC 320-C16 
(IEC60320-C16) 
IEC 320-C16 (IEC60320-
C16) 
Terminal strip 
Power cord rating 
13A 
13A 
10A 
20A @ 100VDC 
Physical specifications 
(H x W x D): 1.58 X 3.25 X 
13.7 in 
Weight: 3 lb 
(1.4 kg) 
(H x W x D): 1.58 X 3.25 
X 12.20 in 
Weight: 2.8 lb 
(1.3 kg) 
(H x W x D): 1.58 X 3.25 
X 12.20 in 
Weight: 2.6 lb 
(1.2 kg) 
(H x W x D): 1.58 X 3.25 
X 12.20 in 
Weight: 2.6 lb 
(1.2 kg) 
Operating temperature 
23 to 113°F (-5 to 45°C) 
Storage temperature 
-40 to 158°F (-40 to 70°C) 
Relative humidity operating and 
non-operating noncondensing 
5 to 90% noncondensing 
Altitude 
10,000 ft. (3000 meters), up to 45°C 
MTBF 
Calculated MTBF must be greater than 300,000 using Telcordia SR-332, Method 1, Case 3. Demonstrated 
MTBF is 500,000 hr (with 90% confidence level). 
EMI and EMC compliance 
FCC Part 15 (CFR 47) Class A 
ICES-003 Class A 
EN 55022 Class A 
CISPR 22 Class A 
AS/NZS 3548 Class A 
BSMI Class A (AC input models only) 
VCCI Class A 
EN 55024, EN300386, EN 50082-1, EN 61000-3-2, EN 61000-3-3 
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN 61000-6-1 
Safety compliance 
UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, CCC, CE Marking 
LED indicators 
“AC OK”: Input power to the power supply is OK 
“PS OK”: Output power from the power supply is OK 
Power Consumption of Standalone Cisco Catalyst 3850 Series Switches 
Table 12 shows power consumption of standalone Cisco Catalyst 3850 Series Switches based on Alliance for 
Telecommunications Industry Solutions (ATIS) testing using IMIX distribution stream traffic, with input voltage of 
115VAC @ 60 Hz and no PoE loading. The values given are the maximum possible power consumption numbers 
under the respective test scenarios.