Chapter 30 System Maintenance
290
Figure 197   Menu 24.10 System Maintenance: Time and Date Setting
The following table describes the fields in this screen.
30.3.1  Resetting the Time
The ZyXEL Device resets the time in three instances:
On leaving menu 24.10 after making changes. 
       Menu 24.10 - System Maintenance - Time and Date Setting
 Use Time Server when Bootup= Daytime (RFC-867)
 Time Server IP Address= 0.0.0.0
 Current Time:                         05 : 53 : 15
 New Time (hh:mm:ss):                  05 : 53 : 00
 Current Date:                         2000 - 01 - 01
 New Date (yyyy-mm-dd):                2000 - 01 - 01
 Time Zone= GMT
           Press ENTER to Confirm or ESC to Cancel:
Table 97   Time and Date Setting Fields
FIELD
DESCRIPTION
Use Time Server 
when Bootup
Enter the time service protocol that your timeserver sends when you turn on the 
ZyXEL Device. Not all timeservers support all protocols, so you may have to check 
with your ISP/network administrator or use trial and error to find a protocol that 
works. The main differences between them are the format. 
 Daytime (RFC 867) format is day/month/year/time zone of the server.
 Time (RFC-868) format displays a 4-byte integer giving the total number of 
seconds since 1970/1/1 at 0:0:0.
 NTP (RFC-1305) the default, is similar to Time (RFC-868).
 None enter the time manually. 
Time Server IP 
Address
Enter the IP address or domain name of your timeserver. Check with your ISP/
network administrator if you are unsure of this information. The default is 
tick.stdtime.gov.tw
Current Time
This field displays an updated time only when you reenter this menu.
New Time
Enter the new time in hour, minute and second format.
Current Date
This field displays an updated date only when you reenter this menu.
New Date
Enter the new date in year, month and day format.
Time Zone
Press [SPACE BAR] and then [ENTER] to set the time difference between your 
time zone and Greenwich Mean Time (GMT). 
Once you have filled in this menu, press [ENTER] at the message “Press ENTER to Confirm or ESC to 