Status  request  commands
Command
Description
Callback
<Parameter>
Q P W
Q $ S
Q I N
Q A V
Q P M
Q F Z
Q $ L
Q S H
Standby power status
Lamp status
Input signal status
Volume adjustment value
Picture mode status
Freeze status
Lamp run time
AV mute function status
Standard
Dynamic
Cinema
Real
Blackboard
Colorboard
Image 1
Image 2
Image 3
Image 4
< p o w e r   c o n d i t i o n >
< l a m p   c o n d i t i o n >
< i n p u t   s i g n a l >
< p l >
S T D
D Y N
C I N
R E A
B B D
C B D
I M 1
I M 2
I M 3
I M 4
< o f f _ o n >
< a c c t c h >
< o f f _ o n >
NOTE:  If  a  wrong  command  is  received,  the  projector  will  send  an  ER401  command  to  the  computer.
Command  example
To  set  the  volume  to  +30,  send  the  command  as  shown  below.
STX
AVL :
30
ETX
Start
Command
Parameter End
NOTE:  When  sending  commands  without  parameters,  a  colon  (:)  is  not  necessary.
NOTE:  If  a  wrong  command  is  received,  the  projector  will  send  an  ER401  command  to  the  computer.
Parameter  format
Parameter format
Size (Byte)
Definition
<pl>
<off on>
<input signal>
<power condition>
<lamp condition>
<acctch>
3 (1 or 2 bytes also 
possible when 
under control)
1
3
3
1
4
Decimal without signs: 0 to 999 (000, 001, 002...999)
Decimal with signs: -99 to +99 (-99...-01, +00, +01, +02...+99)
 
Callback from the projector is 3 Byte.
0 = off, 1 = on
HD1 = HDMI, RG1 = computer 1, RG2 = computer 2, VID = video, 
SVD = S-Video
000 = power off (standby mode off), 001 = power on (standby mode on)
0 = standby, 1 = lamp on under control, 2 = lamp on,
3 = lamp off under control
Decimal without signs: 0000 – 9999 hours