Zebra HW46211 User Manual

Page of 275
Page 4-36
110XiIIIPlus Maintenance Manual
13185L-002 Rev. A  1/24/06
Section 4
Maintenance
Adjust the Wear Plate (Balance) Position 
Adjusting the wear plate position changes the pressure across the width of the printhead 
and platen roller. If uneven printing occurs when the toggle is properly positioned and 
printhead pressure is set correctly, the wear plate may need adjustment.
Refer to 
 for the location of the adjustment screws used in the following 
procedure.
1. Enter Configuration Mode and decrease the darkness setting until the Pause Key 
Self Test labels are a charcoal-gray color.
2. Slightly loosen the two screws on the wear plate.
Figure 4-21.   Wear Plate Adjustment
3. Adjust the wear plate eccentric clockwise to increase pressure on the main frame 
side of the label or adjust it counterclockwise to increase pressure on the outboard 
side of the printer.
Caution:
Wear plate position adjustment rarely needs to be performed. Do not perform 
this adjustment unless you have been trained to do so. If the procedure is not 
done correctly, print quality will be adversely affected.
Toggle
Adjusting
Nuts
Strip Plate
Positioning Screw
Wear Plate
Screws
Eccentric
Notes • Print Pause Key Test labels while adjusting the wear plate eccentric 
and check for even printing.
Adjust the wear plate eccentric by turning it by hand or with an open-end 
wrench or pliers. Make very small adjustments and check the results.
Wear plate adjustments can adversely affect all adjustments. Additional 
adjustments may be necessary.