Zebra HW46211 User Manual

Page of 275
13185L-002 Rev. A  1/24/06
110XiIIIPlus Maintenance Manual
Page 4-75
Maintenance
Section 4
15. Reinstall the electronics cover.
16. Reconnect the data cables and the AC power cord.
17. Turn the printer On (l).
18. Refer to 
.
19. If you receive a Ribbon Error, check all the steps of the installation. Ensure the 
sensor power connector is fully seated in connector P5 on the main logic board.
Replace the Take-Label Sensor
Remove the Sensor 
1. Refer to 
. Turn the printer Off (O) and remove the AC 
power cord and data cables.
2. Open the media cover.
3. Refer to 
4. Cut all cable ties around the sensor cables and remove the sensor cables from the 
cable clamps.
5. Refer to 
 and remove the screws that secure the upper and lower take-
label sensors.
6. Remove the take-label sensor connectors from the main logic board P1 and P2.
7. Remove the take-label sensors and cables, carefully pulling the connectors through 
the main frame.
Caution:
Unless indicated otherwise, turn the printer Off (O) and disconnect the printer 
from the power source before performing the following maintenance.
Caution:
This installation must be performed by a qualified service technician.