Zebra HW46211 User Manual

Page of 275
Page 1-8
110XiIIIPlus Maintenance Manual
13185L-002 Rev. A 1/24/06
Section 1
System Description
Electrical Requirements
Auto-ranging 90–264 VAC; 48–62 Hz 
5 Amps for entire AC voltage range
25 Watts standby power consumption
200 Watts maximum power consumption for 110XiIIIPlus-Series 
(printing 100% black at 6 ips)
Bi-National UL 60950 3rd edition; Certified to CAN/CSA-C22.2 No. 60950-00 
Third edition; IEC 950/EN60950:1992 with amendments 1 through 4 (CB 
Scheme); EN55022: 1998 Class B; EN55024: 1998; EN61000-3-2, 3 with 
amendment A12; Canadian ICES-003, Class B; Argentina 92/98 Phase 3; 
Australia AS/NZS 3548; R.O.C. CNS 13438
CISPR22B-FCC and Canadian DOC class A-Compliant
CE-mark compliant
Power Cord Specifications
The overall length must be less than 9.8
′ (3.0 m).
It must be rated for at least 5 A, 250 V.
Refer  to 
The chassis ground (earth) must be connected to ensure safety 
and reduce electromagnetic interference. The ground connection is handled by the 
third wire (earth) in the power cord.
The AC power plug and IEC 320 connector must bear the certification mark of at 
least one of the international safety organizations shown in 
.
Figure 1-2.   AC Power Cord
Figure 1-3.   International Safety Organizations Symbols
AC power
plug for
your country
3-conductor
<HAR> cable
IEC 320
connector
Contact
view
Neutral
Live
Earth