Zebra HW46211 User Manual

Page of 275
Page 1-12
110XiIIIPlus Maintenance Manual
13185L-002 Rev. A 1/24/06
Section 1
System Description
Communication Buffer
The size of the buffer is 5000 characters. As data is received by the processor monitors the 
number of characters in the buffer. If the buffer is filled beyond 4744 characters, the Data 
Terminal Ready (DTR) control leads to the off condition (negative voltage) or transmits an 
XOFF (DC-3) control character to the host. When the buffer empties below 4250 
characters, DTR turns on (positive voltage) or transmits an XON (DC-1) control character 
to the host.
Serial Data Communication Interface Overview
The connection for this standard interface is made through the female DB-9 connector on 
the rear panel. A DB-9 to DB-25 interface module is available for all RS-232 connections 
through a DB-25 cable.
For all RS-232 input and output signals, the printer follows the specifications of the (EIA) 
RS-232 and (CCITT) V.24.
The table below shows the pin configuration and function of the rear panel serial data 
connector on the printer.
Pin No.
Name
Description
1
Not connected
2
RXD
Receive data—data input to printer
3
TXD
Transmit data—data output from printer
4
DTR
Data terminal ready—output from printer
5
SG
Signal ground
6
DSR
Data set ready—input to printer
7
RTS
Request to send—output from printer
8
CTS
Clear to send—input to printer
9
+5 VDC
+5 VDC signal output
Notes • Pin 9 is also available as a +5 VDC power source at 750 mA. The 
maximum current draw may be limited by option configuration. To enable this 
capability, a jumper on the computer’s main logic board needs to be installed on 
JP1, pins 2 and 3.
An interface module is required for RS-422/RS-485 interface support.