Zebra HW46211 User Manual

Page of 275
13185L-002 Rev. A 1/24/06
110XiIIIPlus Maintenance Manual
Page 2-39
Operations Overview
Section 2
For any errors, check that your communication parameters are correct. Set the print width 
equal to or less than the label width used for the test.
Press NEXT/SAVE to display CONTROL PREFIX.
Control Prefix Character
The control prefix character is a two-digit hex value. Once configured, this character 
signifies the start of a ZPL/ZPL II control instruction.
Press the left oval key to move to the next digit position, and press the right oval key to 
increase the value of the digit. (The displayed H is not entered as part of the value.)
Press NEXT/SAVE to display FORMAT PREFIX.
Format Prefix Character
The format prefix character is a two-digit hex value. Once configured, this character 
signifies the start of a ZPL or ZPL II format instruction.
Press the left oval key to move to the next digit position, and press the right oval key to 
increase the value of the digit. (The displayed H is not entered as part of the value.)
Press NEXT/SAVE to display DELIMITER CHAR.
Note • On diagnostic printouts:
FE indicates a framing error.
OE indicates an overrun error.
PE indicates parity error.
NE indicates noise.
Default: 7E (tilde)
Range:
00–FF (Exclude the values indicated on the ASCII Code Chart in the 
ZPL II Guide Volume II, Appendix B.)
Default: 5E (caret)
Range:
00–FF (Exclude the values indicated on the ASCII Code Chart in the 
ZPL II Guide Volume II, Appendix B.)
CONTROL PREFIX
< >
EH
+
7
FORMAT PREFIX
<^>
EH
+
5