Zebra HW46211 User Manual

Page of 275
13185L-002 Rev. A 1/24/06
110XiIIIPlus Maintenance Manual
Page 2-41
Operations Overview
Section 2
Head Close
This setting determines the action of the media after the opened printhead is closed. 
CALIBRATION recalibrates the media and ribbon sensors, Feed feeds the label to the first 
web, Length calculates the length of the label, and No Motion means the media does not 
move.
Press the right or left oval key to display other selections.
Press NEXT/SAVE to display BACKFEED.
Label Positioning Parameters
Backfeed Sequence
This parameter establishes when backfeed occurs after a label is removed in Peel-Off or 
Cutter Mode. It has no effect in Rewind or Tear Off Mode.
This parameter setting can be superseded by the ~JS instruction when received as part of 
a label format. Refer to the ZPL II Programming Guide.
Press the right oval key for the next choice, or press the left oval key for the previous 
choice.
Press NEXT/SAVE to display LABEL TOP.
Default: Calibration
Selections: Feed, Calibration, Length, No Motion
HEAD CLOSE
CALIBRATION
Default: Default
Selections:
Default, After, Before, Off, 10%, 20%, 30%, 40%, 50%, 60%, 70%, 
80%
BACKFEED
DEFAULT