Zebra HW46211 User Manual

Page of 275
Page 2-46
110XiIIIPlus Maintenance Manual
13185L-002 Rev. A 1/24/06
Section 2
Operations Overview
Set Resynch Mode
This parameter determines how the printer reacts if the label synchronization is lost and 
the label top is not where expected.
FEED MODE—If the label top is not where expected, the printer feeds a blank label to 
find the label top position.
ERROR MODE—If the label top is not where expected, the printer stops, enters 
Pause Mode, displays the message Error Condition Feed Label, flashes the ERROR LED, 
and asserts the Service Required signal (pin 10 on the Applicator Interface Connector).
To resynch the media to the top of the label in Error Mode, press PAUSE to exit the pause 
state. The ERROR LED stops flashing and the Service Required signal is deactivated. The 
action of the printer is determined by the Head Close configuration selection:
Calibration—determines the length of the label.
Feed—feeds the labels to the first registration point.
Length—used in continuous mode to feed the last stored label length.
No Motion—the media does not move. Press FEED to cause the printer to 
resynch to the start of the next label.
Print Controls
The parameters Web Sensor, Media Sensor, Ribbon Sensor, Mark Sensor, Mark Media 
Sensor, Media LED, Ribbon LED, and Mark LED are automatically calculated during the 
calibration procedure and typically do not require adjustment. Refer to the ZPL II 
Programming Guide for further information on these parameters.
Press NEXT/SAVE repeatedly to skip these parameters and go to the
LCD ADJUST display.
Default: Feed Mode
Range: Feed Mode, Error Mode
RESYNCH MODE
FEED MODE
WEB S.
044
-
+
MEDIA S.
079
-
+
RIBBON S. 072
-
+
MARK S.
050
-
+
MARK MED S. 000
-
+
MEDIA S.
079
-
+
RIBBON LED 000
+
MARK LED
000
+