Cisco TRC5 CTS-RMT-TRC5= User Manual

Product codes
CTS-RMT-TRC5=
Page of 45
27
Deployment Details
August 2012 Series
27
Configuring Cisco TelePresence System Profile Series
Process
The recommended Cisco TelePresence System Profile Series endpoints are 
multipurpose room systems that you can configure using SIP. The configura-
tion steps for this platform are the same as they are for any of the Cisco 
TelePresence System Codec C-Series endpoints. Before getting started, 
you need to collect certain information specific to your site. You can fill in 
the following table. 
Table 4 -  Information you need before configuring SIP endpoints
Item
Cisco SBA 
configuration
Site-specific 
details
System name
85104600@cisco.local
DNS server address
10.4.48.10
DNS domain name
cisco.local
SNMP community name
cisco
NTP server address
10.4.48.17
Time zone
GMT -8 (Pacific)
SIP URI
85104600@cisco.local
SIP Proxy 1 address
10.4.48.130
SIP Proxy 2 address
10.4.48.131
Procedure 1 
Configure Profile connectivity to the LAN
To ensure that video traffic is prioritized appropriately, you must configure 
the Catalyst access switch port where the video endpoint is connected to 
trust the DSCP markings. The easiest way to do this is to clear the interface 
of any previous configuration and then, apply the egress QoS macro that 
was defined in the access-switch platform configuration of the SBA—LAN 
Deployment Guide.  
Step 1:  
Login to the Catalyst switch with a username that has the ability to 
make configuration changes. 
Step 2:  
Clear the interface’s configuration on the switch port where the 
video endpoint is connected.
default interface 
GigabitEthernet1/0/23
Step 3:  
Configure the port as an access port and apply the Egress QoS 
policy. 
interface 
GigabitEthernet1/0/23
 description Profile 42
 switchport access vlan 
64
 switchport host
 macro apply EgressQoS
Procedure 2 
Configure the Profile series platform
The endpoint uses the Dynamic Host Configuration Protocol (DHCP) to 
automatically obtain its IP address from the network services layer of the 
Cisco SBA platform. The configuration of the SIP endpoint is done with the 
remote control. 
Using the remote control, the following steps allow you to verify the end-
point is getting the correct IP information from the server. You also need to 
manually set the time to allow the NTP service to take over after it is properly 
configured.
Step 1:  
Connect all of the cables as specified in the endpoint installation 
guide, and turn on the power switch. Wait several minutes for the system to 
power up.