Bosch ISW-BIN1-S135X F.01U.004.066 User Manual

Product codes
F.01U.004.066
Page of 3
 
Intrusion Alarm Systems | wLSN Inertia Sensor
wLSN Inertia Sensor
 
www.boschsecurity.com
 
 
 
u
Holding clip allows sensor pivoting in any direction
and enabling detector mounting in any orientation
u
Minor and Gross Attack settings
u
Option of using an internal reed switch with an ex-
ternal magnet assembly
u
Externally-visible LED indicating operational sensitiv-
ity setting and RF signal strength
u
RF Signal Strength (RFSS) mode to determine suita-
bility of chosen installation location
The wLSN Inertia Sensor is used for monitoring doors
and windows. In addition to an inertia sensor, it has in-
ternal reed switches (one on each side) that can be
used with an external magnet assembly.
Functions
Gross or Minor Attack Movement Settings
The wLSN Inertia Sensor has two settings (gross at-
tack or minor attack) each of which has sensitivity ad-
justments. If the minor attack setting is enabled, you
can program four or eight repetitive taps. Use the mi-
nor attack setting for sensitive areas. Use the minor at-
tack setting for sensitive areas.
If minor attack is disabled, the inertia sensor reacts to
only major attack movement. The gross attack move-
ment has four sensitivity settings.
RF Signal Strength Mode
Removing the device cover and pressing the tamper
switch four times within 10 seconds of battery installa-
tion activates the RF signal strength mode. The LED
lights steadily for 5 sec and then begins to flash. A
slow flash (approximately 1 sec on, 1 sec off) indicates
insufficient signal reception. A rapidly flashing LED
(approximately five times as fast as the slow flash) in-
dicates the device is receiving sufficient signal from
the wLSN Hub.
Certifications and Approvals
Additionally, the wLSN Inertia Sensor has been designed to comply with
the following standard:
EN50131-1 Grade 2, Environmental class II.
Region
Certification
Europe
CE
CE 1999/5/EC, EN50130-4: 1996 +A1:
1998 +A2: 2003, ETSI EN 300 220-1
V1.3.1: 2000-09, ETSI EN 301 489-1
V1.4.1: 2002-08, ETSI EN 301 489-3
V1.4.1: 2002-08, IEC60950-1: 2001,
EN60950-1:2001 +A11:2004,
EN55022/ANSI C63.4: 2003,
EN61000-4-2: 1995 +A1: 1998 +A2:
2001, EN61000-4-3: 2002 +A1: 2003
+A2: 2005, EN61000-4-4: 1995 +A1:
2001 +A2: 2001, EN61000-4-5: 1995
+A1: 2001, EN61000-4-6: 1996 +A1:
2001 +A2: 2001 +A3: 2005,
EN61000-4-11: 1994 +A1: 2001, TS
50131-2-6:2004 (Version 1)
Belgium
INCERT
B-509-0056
Installation/Configuration Notes
Compatibility Information
The wireless Local SecurityNetwork (wLSN) including
the wLSN Inertia Sensor is compatible with the Easy
Series Control Panel.