Intel i3-3130M AW8063801111500 User Manual

Product codes
AW8063801111500
Page of 112
Electrical Specifications 
76
Datasheet, Volume 1
7.3
Processor Clocking (BCLK[0], BCLK#[0])
The processor uses a differential clock to generate the processor core operating 
frequency, memory controller frequency, system agent frequencies, and other internal 
clocks. The processor core frequency is determined by multiplying the processor core 
ratio by the BCLK frequency. Clock multiplying within the processor is provided by an 
internal phase locked loop (PLL) that requires a constant frequency input, with 
exceptions for Spread Spectrum Clocking (SSC).
The processor’s maximum non-turbo core frequency is configured during power-on 
reset by using its manufacturing default value. This value is the highest non-turbo core 
multiplier at which the processor can operate. If lower maximum speeds are desired, 
the appropriate ratio can be configured using the FLEX_RATIO MSR. 
7.3.1
Phase Lock Loop (PLL) Power Supply
An on-die PLL filter solution is implemented on the processor. Refer to 
 for DC 
specifications.
7.4
V
CC
 Voltage Identification (VID)
The processor
 
uses three signals for the serial voltage identification interface to support 
automatic selection of voltages. 
 specifies the voltage level corresponding to 
the eight bit VID value transmitted over serial VID. A ‘1’ in this table refers to a high 
voltage level and a ‘0’ refers to a low voltage level. If the voltage regulation circuit 
cannot supply the voltage that is requested, the voltage regulator must disable itself. 
VID signals are CMOS push/pull drivers. Refer to 
 for the DC specifications for 
these signals. The VID codes will change due to temperature and/or current load 
changes to minimize the power of the part. A voltage range is provided in 
The specifications are set so that one voltage regulator can operate with all supported 
frequencies.
Individual processor VID values may be set during manufacturing so that two devices 
at the same core frequency may have different default VID settings. This is shown in 
the VID range values in 
. The processor
 
provides the ability to operate while 
transitioning to an adjacent VID and its associated voltage. This will represent a DC 
shift in the loadline.
Note:
At condition outside functional operation condition limits, neither functionality nor long 
term reliability can be expected. If a device is returned to conditions within functional 
operation limits after having been subjected to conditions outside these limits, but 
within the absolute maximum and minimum ratings, the device may be functional, but 
with its lifetime degraded on exposure to conditions exceeding the functional operation 
condition limits.