Bosch VEZ-211-IWCS User Manual

Page of 756
Illumination | Explosion Protected Illumination | 343
EX60LED Explosion
Protected Infrared Illumi-
nator
Features
▶ Heavy Duty Extruded Aluminum Design
▶ Class I, Div 1 & 2, Group A, B, C, D
▶ Class II, Div 1 & 2, Group E, F, G
▶ Class III
▶ Equipped in CSA NRTL approved housing
▶ Easy access slide tray for camera guide
▶ 3/8 in. chemical resistant window
▶ 100 LEDs for 60 ft. (18.3 m) performance
▶ 3/4 NPT Conduit Hole Input
The EX60LED series are tough, compact, explosion
protected infrared illuminators for effective nighttime
illumination in hazardous environments.
Its Class I, Groups A and B ratings for Acetylene and
Hydrogen makes this housing unique in industry.
The extended design of the EX60LED accommodates a
powerful, high-efficiency 100 LED array that provides up
to 60ft infrared illumination with IR sensitive cameras.
Options for completely covert operation at 940 nm, as
well as 30º and 60º beams are available for special
applications.
The EX60LED is also designed to CCTV industry standards
for mounting hardware and motorized pan/tilt devices.
Functions
Applications
Chemical factories
Petroleum refineries, oil and gas processing
Utility gas plants
Grain elevators, flour mills
Dry cleaning plants
Pharmaceutical plants
Coal and carbon processing
Aircraft hangars
Spray finishing areas
Munitions and fuel storage facilities
Certifications and Approvals
Region
Certification
Canada
CSA
CSA-NRTL
LR 113310
Class
9098 01 / 81 Miscellaneous - for Hazardous Locations
Safety
UL / CSA
UL 508, Sixteenth Edition - Industrial Control Equip-
ment
UL 698, Eleventh Edition - Industrial Control Equip-
ment for Use in Hazardous (Classified) Locations
UL 1203 Explosion-Proof and Dust-Ignition-Proof Elec-
trical Equipment for Use in Hazardous (Classified) Lo-
cations
CSA C22.2 No.0-M1991 General Electrical Require-
ments
CSA C22.2 No.0.4-M1982 Bonding and Grounding of
Electrical Equipment (Protective Grounding)
CSA C22.2 No.25-M1966 Enclosures for Use in Class II
Groups E, F, and G Hazardous Locations
CSA C22.2 No.30-M1986 Explosion-proof Enclosures
for Use in Class I Hazardous Locations
CSA C22.2 No.94-M1991 Special Purpose Enclosures
CSA C22.2 No.142-M1987 Process Control Equip-
ment
Class I, Div 1, 2, Groups A, B, C, D
Class II, Div 1, 2, Groups E, F, G
Class III
Operational
Temperature Code T6 at maximum ambient tempera-
ture 55ºC (131ºF)
Environmental
CSA / NEMA TYPE 4
Note
Product is not ATEX certified.
Technical Specifications
Model
EX60LED8W
EX60LED8M
EX60LED9M
LED Type
850 nm
850 nm
940 nm
LED Beam Angles 60° wide
30° medium
30° medium
Number of LEDs
100
Power Supply
12 VDC or 24 VAC
Power Consumption
15 W (max.)
Construction
Extruded copper-free anodized aluminum with
three 3/4-inch NPT conduit entries
View window
3/8-inch tempered glass
Brackets
U-bracket and stainless steel straps included
www.boschsecurity.com 