7205-550                    Load ID is A17002A9 
  
80GB VXA Tape drive 
7206-VX2                    Load ID is A170029C 
z
Run genucode to download the microcode to the tape drive:  
/tmp/genucode -s rmt0 {rmt0 is Tape drive name}  
Note:  
z
Genucode will not prompt you before executing the download. 
z
It is NOT necessary to recycle (powering the OFF then ON) the system or the tape drive to have the tape drive 
microcode active. 
z
If you are going to recycle the system or the tape drive, MAKE SURE the microcode download IS COMPLETE. If 
the tape drive is recycled prior to the microcode download being complete, damage may be done to the internal 
programming of the drive requiring the drive to have to be replaced. 
z
If you try multiple microcode downloads to the drive without recycling the tape drive the microcode download may 
fail.  
Genucode Return Codes
 
Program failed with Return_code: -xx  
 NO INIT ODM     (-1) 
 EXIT MAIN PANEL (-2) 
 EXIT SELECT RES (-3) 
 NO OPEN DSDATA  (-4) 
 DSDATA ERROR    (-5) 
 EXIT SELECT DEV (-6) 
 INQUIRY FAILED  (-7) 
 MISMATCHED PARM (-8) 
 EXIT CONF DL    (-9) 
 DOWNLOAD FAILED (-10) 
 NO RES DEVS     (-11) 
 EXIT CFGRES DEV (-12) 
 CFGREQ FAIL     (-13) 
 EXIT RES FAIL   (-14) 
 RESTORE FAIL    (-15) 
 NO DL DEVS      (-16) 
 NO OPEN DEV     (-17) 
 BAD INPUT PARM  (-18) 