Daewoo RN-331NPW User Manual

Page of 38
2. FUNCTIONS
- ERROR DISPLAY 
   - If appliance has any errors, LED on the Main PCB is flickering.   
   - If the appliance is normal (no error),  LED IS off. 
 
A. 'R1' ERROR 
  : It happens when R-Sensor is OPEN or SHORT. 
  (1) LED DISPLAY: Shortly flickering(0.3sec.) 1 times. 
  (2) CONTROL:  
      Controlled by the following condition of RT 
                                                                                       
 
 
 
 
     
 
If 'RT ERROR' happens at the same time, “COMP. ON/OFF Operating Time” is 16min/24min. 
  (3) RELEASE: When R-Sensor is working normally. 
 
B. 'RT' ERROR 
  : It happens when RT-Sensor is OPEN or SHORT. 
  (1) LED DISPLAY: Shortly flickering(0.3sec.) 2 times. 
  (2) CONTROL: Delete the conditions of 'RT-sensor Control' and operate normally. 
  (3) RELEASE: When RT-Sensor is working normally. 
 
C. 'd1' ERROR 
  : It happens when D-Sensor is OPEN or SHORT. 
  (1) LED DISPLAY: Shortly flickering(0.3sec.) 3 times. 
  (2) CONTROL: Return to next limit defrost time (40 min) 
  (3) RELEASE: When D-Sensor is working normally. 
 
D. 'DR' ERROR  
   : It happens when the system senses door opens more than 1 hour.  
   (1) LED DISPLAY: Shortly flickering(0.3sec.) 4 times. 
   (2) CONTROL: Delete function relating to door switch sensing 
   (3) RELEASE:  When sensing close from door S/W. 
 
 
 
 When pusing 'TEST KEY' on the main PCB,  
       LED is long(1.0sec.) flickering several times. 
    ex.  'Forced Defrost Mode:' long flickering 2 times    
 
LED Lamp 
CONTROL OBJECT 
INPUT 
Sensor Error 
2-9. Error Display
 
6/34 
~13 
10/30 
~19 
16/24 
~29 
20/20 
29
~
 
    COMP. Operating ON/OFF TIME 
                                        (unit:min.) 
    RT sensor TEMP        (unit:
℃)
 
To Confirm Errors: 
Check LED on the main PCB   
 
- The Priorities of Error : 
    R1
RT
D1
DR 
DR Switch 
4times 
DR 
D sensor 
3times 
d1 
RT sensor 
2times 
RT 
R sensor 
1time 
R1 
ERROR 
LED 
CODE 
flicker 
17