LevelOne 4 FE + 1 MM SC Unmanaged Switch -40 ~ 75C, DIN-rail IES-0520-v1 Leaflet

Product codes
IES-0520-v1
Page of 2
Order Information
IES-0520 
4 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail
Specifications
Package Contents
IES-0520
Quick Installation Guide
www.level1.com      one world_one brand_one level_
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
MTBF
54.87 years
Technology
Standards
 IEEE802.3 10BASE-T, IEEE802.3u 100BASE-
TX/100BASE-FX,IEEE802.3x
Forward and 
 Filtering Rate
 14,880pps for 10Mbps
 148,810pps for 100Mbps
Packet Buffer 
Memory
 768K bits
Processing 
 Type
 Store-and-Forward
 Half-duplex back-pressure and IEEE802.3x full-duplex 
Address Table 
 Size
 2048 MAC addresses
Environment
Operating 
Temperature
 -40°C to 75°C (-40°F to 167°F)
Tested @ -40°C to 85°C (-40°F to 185°F)
Storage 
 Temperature
 -40°C to 85°C (-40°F to 185°F)
Ambient 
 Relative 
 Humidity
5% to 95% (non-condensing)
Regulatory Approvals
ISO
 Manufactured in an ISO9001 facility
Safety
 UL508
EMI
 FCC Part 15, Class A, VCCI
 EN61000-6-3
-  EN55022
-  EN61000-3-2
-  EN61000-3-3
EMS
 EN61000-6-2
-  EN61000-4-2 (ESD Standards)
Contact: + / - 4KV; Criteria B
Air: + / - 8KV; Criteria B
-  EN61000-4-3 (Radiated RFI Standards)
10V/m, 80 to 1000MHz; 80% AM Criteria A
3V/m, 1400 to 2000MHz; 80% AM Criteria A
1V/m, 2000 to 2700MHz; 80% AM Criteria A
-  EN61000-4-4 (Burst Standards)
Signal Ports: + / - 4KV; Criteria B
D.C. Power Ports: + / - 4KV; Criteria B
-  EN61000-4-5 (Surge Standards)
Signal Ports: + / - 1KV; Line-to-Line; Criteria B
D.C. Power Ports: + / - 0.5KV; Line-to-Earth; Criteria B
-  EN61000-4-6 (Induced RFI Standards)
Signal Ports: 10Vrms @ 0.15 - 80MHz; 80% AM Criteria A
D.C. Power Ports: 10Vrms @ 0.15 - 80MHz; 80% AM 
Criteria A
-  EN61000-4-8 (Magnetic Field Standards)
30A/m @ 50, 60Hz; Criteria A
Environmental 
 Test 
 Compliance
 IEC60068-2-6 Fc (Vibration Resistance)
5g @ 10 - 150Hz, Amplitude 0.35mm 
(Operation/Storage/Transport)
 IEC60068-2-27 Ea (Shock)
25g @ 11ms (Half-Sine Shock Pulse; Operation)
50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
 IEC60068-2-32 Ed (Free Fall)
1M (3.281ft.) 
Power
Input
 Input Voltage: 12 to 48VDC (Terminal Block); 
12VDC (DC Jack)
Power 
 Consumption
 6.3W Max. 0.48A @ 12VDC, 0.24A @ 24VDC  
0.13A @ 48VDC
Overload 
Current 
Protection
 Present
Reverse 
Polarity 
Protection
 Present
Mechanical
Casing
 Aluminum case
Dimensions
 50mm (W) x 110mm (D) x 135mm (H)
(1.97" (W) x 4.33" (D) x 5.31" (H))
Weight
 0.8Kg (1.76lbs.)
Installation
 DIN-Rail (Top hat type 35mm), Panel Mounting
Interface
Ethernet Port
 10/100BASE-TX: 8, 6, 5 or 4 ports
 100BASE-FX: 0, 1, 2 or 4 ports
LED Indicators
Per Unit: Power Status (Power 1, Power 2,  Fault)
 Per Port: 10/100TX, 100FX: Link/Activity (Green), 
Speed (Yellow)
Alarm Contact
 One relay output with current 1.5A @ 24VDC