Intel E5-4657L v2 CM8063501285605 User Manual

Product codes
CM8063501285605
Page of 258
Boxed Processor Specifications
250
Intel® Xeon® Processor E5-1600/E5-2600/E5-4600 Product Families
Datasheet Volume One
Figure 10-8. Boxed Processor Heat Sink Volumetric (1 of 2)
1
3
4
5
6
7
8
B
C
D
A
1
2
3
4
5
6
7
8
B
C
D
A
2200 MISSION COLLEGE BLVD. P.O. BOX 58119 SANTA CLARA, CA 95052-8119
R
4X 12.00
+1.00  0
0.472
+0.039 -0.000
[]
4X 12.00
+1.00  0
0.472
+0.039 -0.000
[]
64.00
  MAX.
[2.520
]
B
91.50
 0 -0.25
3.602
+0.000 -0.009
[]
A
91.50
 0 -0.25
3.602
+0.000 -0.009
[]
C
E95132
1
B
DWG. NO
SHT.
REV
SHEET 1
 OF 
2
DO NOT SCALE DRAWING
SCALE: 1
B
E95132
D
REV
DRAWING NUMBER
SIZE
ROMLEY 2U HS VOLUMETRIC,
DIE CAST BASES ONLY
TITLE
EASD / PTMI
DEPARTMENT
SEE NOTES
SEE NOTES
FINISH
MATERIAL
 
 
DATE
APPROVED BY
-
-
3/29/10
D. LLAPITAN
DATE
CHECKED BY
3/29/10
N. ULEN
DATE
DRAWN BY
3/29/10
N. ULEN
DATE
DESIGNED BY
         UNLESS OTHERWISE SPECIFIED      INTERPRET DIMENSIONS AND TOLERANCES       IN ACCORDANCE WITH ASME Y14.5-1994         DIMENSIONS ARE IN MILLIMETERS                  TOLERANCES:             .X 
#
 .5   Angles  
#
 1.0
$
           .XX 
#
 0.25
          .XXX 
#
 0.127
THIRD ANGLE PROJECTION
    
REVISION HISTORY
ZONE
REV
DESCRIPTION
DATE
APPROVED
2B2
A
VOLUME FOR DIE CAST GEOMETRY INTEGRATED SPRING/SCREW CUP FEATURE IN TO CAST GEOMETRY
3/29/10
-
B
ROLLED PART TO -002 CHANGED SPRING CUP GEOMETRY TO FIT DELRIN SPACER
7/21/10
   THIS DRAWING CONTAINS INTEL CORPORAT
ION CONFIDENTIAL INFORMATION. IT IS 
DISCLOSED IN CONFIDENCE AND ITS CONT
ENTS
 MAY NOT BE DISCLOSED, REPRODUCED, DI
SPLAYED OR MODIFIED, WITHOUT THE PRI
OR WRITTEN CONSENT OF INTEL CORPORAT
ION.
 NOTES:   1.   THIS DRAWING TO BE USED IN CONJUNCTION WITH      SUPPLIED 3D DATABASE FILE. ALL DIMENSIONS AND TOLERANCES      ON THIS DRAWING TAKE PRECEDENCE OVER SUPPLIED FILE. 2.   PRIMARY DIMENSIONS STATED IN MILLIMETERS,      [BRACKETED] DIMENSIONS STATED IN INCHES.      CRITICAL TO FUNCTION DIMENSION. 3.   ALL DIMENSION AND TOLERANCES PER ANSI Y14.5-1994. 4.   HEAT SINK VOLUMETRIC.  ALL HEAT SINK GEOMETRY      MUST FIT WITHIN THE SPACE DEFINED BY THIS DRAWING.. 6.   REMOVE ALL BURRS, SHARP EDGES, GREASES, AND/OR      SOLVENTS AFTER MACHINING AND FIN ASSEMBLY. 7.   LOCAL FLATNESS ZONE .076 MM [0.003"] CENTERED ON      HEAT SINK BASE. 8.   NO EXPOSED CORNER FINS ALLOWED.  CHAMFER ALL      EXPOSED FIN CORNERS TO THE VALUE SPECIFIED.
9
   CRITICAL TO FUNCTION DIMENSION.
 
TOP VIEW
AIRFLOW DIRECTION
SEE NOTE 8
SEE NOTE 4
PARTS LIST
DESCRIPTION
PART NUMBER
ITEM NO
QTY
ROMLEY 2U HS VOLUMETRIC
E95132-002
TOP
T
h
dr
aw
ing
 c
ontain
s in
tel
 c
o
rp
or
atio
n inf
ormati
o
n.
  Its
 c
o
n
ten
ts
 m
ay no
t be re
pr
odu
ce
d
dis
p
la
ye
d,
 or
 m
o
dif
ie
d
 with
out
 t
h
pr
io
writ
ten
 c
ons
ent
 o
f In
tel
 Co
rpo
ratio
n.