iNVErTEr SYSTEM. The inverter range provides greater 
efficiency, more comfort and less noise than classic air 
conditioners. The inverter system provides more precise 
temperature control, and keeps the ambient temperature 
constant with lower energy consumption and a significant 
reduction in noise and vibration levels.
A
 class
energy saving
SupEr QuiET MoDE. Thanks to its latest generation com-
pressor and its twin blade fan, our outdoor unit is one of 
the most silent on the market. The indoor unit emits an 
almost imperceptible 22 dB.
SUPER QUIET
Silent air
22 dB
powErFuL MoDE. The rapid and effective powerful mode 
is ideal for when you come home on the hottest or coldest 
days. it works at maximum power to reach the desired 
temperature in 15 minutes.
High
air flow
POWERFUL MODE
5 YEArS. 
warranty on the 
compressor.
5 year
compressor
warranty
www
.eggeassociats.net
coMfoRT
·  Super Quiet mode
·  Powerful mode
·  Automatic vertical airflow control
·  Hot start mode
·  Automatic restart
EaSY INSTallaTIoN aNd MaINTENaNcE
·  Maximum connection distance 15 m
·  Removable, washable panel
Kit
KIT-UE9-pKE
KIT-UE12-pKE
indoor
CS-uE9pKE
CS-uE12pKE
outdoor
Cu-uE9pKE
Cu-uE12pKE
Cooling capacity
Nominal (Min - Max)
kw
2.50 (0.90-3.00)
3.50 (0.90-3.90)
Nominal (Min - Max)
kCal/h
2,150 (770-2,580)
3,010 (770-3,350)
EEr 
1)
Nominal (Min - Max)
Energy Saving
3.57 (4.74-3.00)
3.47 (5.29-3.25)
SEEr
Nominal
Energy Saving
5.6 
a+
5.6  
a+
pdesign (cooling)
2.5
3.5
power input Cooling
Nominal (Min - Max)
kw
0.70 (0.19-1.00)
1.01 (0.17-1.2)
Annual Energy Consumption (cooling)
kwh
156
219
Heating capacity
Nominal (Min - Max)
kw
3.30 (0.90-3.90)
4.25 (0.90-4.90)
Nominal (Min - Max)
kCal/h
2,840 (770-3,350)
3,660 (770-4,210)
Heating capacity at -7°C
Nominal
kw
2.83
3.55
Cop
 1)
Nominal (Min - Max)
Energy Saving
4.02 (5.29-3.39) 
3.79 (6.00-3.35) 
SCop
Nominal
Energy Saving
3.4 
a
3.4 
a
pdesign at -10 ºC
kw
2.5
3.2
power input Heating
Nominal (Min - Max)
kw
0.82 (0.17-1.15)
1.12 (0.15-1.46)
Annual Energy Consumption (heating)
kwh
1029
1318
indoor unit
power source
V
230
230
recommended Fuse
A
recommended power cable section
mm
Connection indoor / outdoor
mm
4 x 1.5
4 x 1.5
Current (Nominal)
Cooling
A
3.3
4.7
Heating
A
3.8
5.2
Max. current
A
6.3
8.4
Air Volume
Cooling / Heating
m
3
/h
750 / 666
750 / 750
Moisture removal volume
l/h
1.4
2.0
Sound pressure Level
 2)
Cooling (Hi / Lo / S-Lo)
dB(A)
42 / 27 / 22
42 / 30 / 22
Heating (Hi / Lo / S-Lo)
dB(A)
42 / 27 / 25
42 / 33 / 25
Sound power Level
Cooling (Hi)
dB
58
58
Heating (Hi)
dB
58
58
Dimensions
 3)
H x w x D
mm
290 x 848 x 213
290 x 848 x 213
Net weight
kg
8
8
Air purifier filter
Anti Bacterial filter
Anti Bacterial filter
outdoor unit
Air Volume
Cooling / Heating
m
3
/h
1,902 / 1,842
1,956 / 1,896
Sound pressure Level
 2)
Cooling (Hi)
dB(A)
47
48
Heating (Hi)
dB(A)
48
50
Sound power Level
Cooling (Hi)
dB
63
64
Heating (Hi)
dB
64
66
Dimensions
 3)
H x w x D
mm
540 x 780 x 289
540 x 780 x 289
Net weight
kg
23
26
piping connections
Liquid pipe
inch (mm)
1/4” (6.35)
1/4” (6.35)
gas pipe
inch (mm)
3/8” (9.52) 
3/8” (9.52) 
refrigerant Loading
r410A
kg
0.77
0.86
Elevation difference (in/out)
 4)
Max
m
10
10
piping length
Min / Max
m
3-15
3-15
piping length without refrigerant increase
Max
m
7
7
Additional gas
g/m
20
20
operating range
Cooling Min / Max
°C
+16 / +43
+16 / +43
Heating Min / Max
°C
-10 / +24
-10 / +24
cU-UE9pKE
cU-UE12pKE
rating Conditions: Cooling indoor 27 ºC DB / 19 ºC wB. Cooling outdoor 35 ºC DB / 24 ºC wB. Heating indoor 20 ºC DB. Cooling outdoor 7 ºC DB / 6 ºC wB. (DB: Dry Bulb; wB: wet Bulb) / This model is not suitable to use in heating mode below -5 ºC with continuous operation (24 h operation).
1) EEr and Cop classification is at 230 V in accordance with Eu directive 2002/31/EC. / 2) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. / 3) Add 70 mm for 
piping port. / 4) when installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
Wall MoUNTEd UE TYpE // STaNdaRd INVERTER
KIT-UE9-pKE // KIT-UE12-pKE
HEalTHY aIR
·  Odour-removing function
·  Anti-mould filter
ENERGY, EffIcIENcY aNd EcoloGY
·  Inverter system
·  R410A refrigerant gas
EaSE of USE
·  12-hr timer
·  User friendly infrared remote control