Panasonic CU-RE24PKE-3 Leaflet

Page of 2
6.7 A++
SEER
SEASONAL ENERGY 
EFFICIENCY RATIO
SUPER QUIET
Silent air
22 dB
Inverter models are powerful and efficient and are always there when you need them.
WALL MOUNTED RE-3 TYPE
STANDARD INVERTER
SEER and SCOP: For KIT-RE18-PKE-3. SUPER QUIET: For RE9 and RE12.
A
 class
energy saving
4.1 A+
SCOP
SEASONAL COEFFICIENT  
OF PERFORMANCE
Kit
KIT-RE9-PKE-3
KIT-RE12-PKE-3
KIT-RE15-PKE-3
KIT-RE18-PKE-3
KIT-RE24-PKE-3
Indoor
CS-RE9PKE-3
CS-RE12PKE-3
CS-RE15PKE-3
CS-RE18PKE-3
CS-RE24PKE-3
Outdoor
CU-RE9PKE-3
CU-RE12PKE-3
CU-RE15PKE-3
CU-RE18PKE-3
CU-RE24PKE-3
Cooling capacity
Nominal (Min - Max)
kW
2.50 (0.90-3.00)
3.50 (0.90-3.90)
4.20 (1.00-4.60)
5.00 (0.98-6.00)
6.80 (0.98-8.10)
Nominal (Min - Max)
kCal/h
2,150 (770-2,580)
3,010 (770-3,350)
3,610 (860-3960)
4,300 (840-5,160)
5,850 (840-6,970)
EER 
1)
Nominal (Min - Max)
Energy Saving 3.57 (4.74-3.00) 
A
3.47 (5.29-3.25) 
A
3.33 (4.76-2.78) 
A
3.40 (3.50-2.96) 
A
3.24 (2.58-3.03) 
A
SEER
Nominal
Energy Saving 5.6 
A+
5.6 
A+
5.6 
A+
6.7 
A++
5.9 
A+
Pdesign (cooling)
2.5
3.5
4.2
5.0
6.8
Power input Cooling
Nominal (Min - Max)
kW
0.70 (0.19-1.00)
1.01 (0.17-1.2)
1.26 (0.21-1.65)
1.47 (0.28-2.03)
2.10 (0.38-2.67)
Annual Energy Consumption (Cooling) 
2)
kWh
156
219
263
261
403
Heating capacity
Nominal (Min - Max)
kW
3.30 (0.90-4.10)
4.25 (0.90-5.10)
5.00 (0.90-6.80)
5.80 (0.98-8.00)
8.60 (0.98-9.90)
Nominal (Min - Max)
kCal/h
2,840 (770-3,530)
3,660 (770-4,390)
4,300 (770-5850)
4,990 (840-6,880)
7,400 (840-8,510)
Heating capacity at -7°C
Nominal
kW
3.00
3.70
4.93
4.98
6.13
COP 
1)
Nominal (Min - Max)
Energy Saving 4.02 (5.29-3.57) 
A
3.79 (6.00-3.49) 
A
3.61 (4.28-2.98) 
A
3.77 (2.88-3.08) 
A
3.28 (2.18-3.14) 
C
SCOP
Nominal
Energy Saving 3.4 
A
3.4 
A
3.4 
A
4.1 
A+
3.4 
A
Pdesign at -10 °C
kW
2.5
3.2
3.6
4.4
5.5
Power input Heating
Nominal (Min - Max)
kW
0.82 (0.17-1.15)
1.12 (0.15-1.46)
1.385(0.21-2.280)
1.54 (0.34-2.60)
2.62 (0.45-3.15)
Annual Energy Consumption (Heating) 
2)
kWh
1029
1318
1482
1502
2265
Indoor Unit
Power source
V
230
230
230
230
230
Recommended Fuse
A
Recommended power cable section
mm²
Connection (indoor/outdoor)
mm²
4 x 1.5
4 x 1.5
4 x 1.5
4 x 2.5
4 x 2.5
Current (Nominal)
Cooling / Heating
A
3.3 / 3.8
4.7 / 5.2
6.0 / 6.3
6.6 / 6.9
9.6 / 11.8
Max. current
A
6.3
8.4
10.5
11.4
13.9
Air Volume
Cooling / Heating
m³/h
750 / 666
750 / 750
822 / 870
978 / 1,074
1,104 / 1,164
Moisture removal volume
l/h
1.4
2
2.4
2.8
3.9
Sound pressure Level 
3)
Cooling (Hi / Lo / S-Lo) dB(A)
42 / 27 / 22
42 / 30 / 22
44 / 31 / 29
44 / 37
47 / 38
Heating (Hi / Lo / S-Lo) dB(A)
42 / 27 / 25
42 / 33 / 25
46 / 34 / 28
44 / 37
47 / 38
Sound power Level
Cooling (Hi)
dB
58
58
60
60
63
Heating (Hi)
dB
58
58
62
60
63
Dimensions
H x W x D
mm
290 x 848 x 213
290 x 848 x 213
290 x 848 x 213
290 x 1,070 x 240
290 x 1,070 x 240
Net weight
kg
8
8
8
12
12
Air purifier filter
Outdoor Unit
Air Volume
Cooling / Heating
m³/h
1,902 / 1,842
1,956 / 1,896
1,956 / 1,956
2,352 / 2,274
3,012 / 3,012
Sound pressure Level 
3)
Cooling (Hi)
dB(A)
47
48
49
47
52
Heating (Hi)
dB(A)
48
50
51
47
52
Sound power Level
Cooling (Hi)
dB
63
64
65
61
66
Heating (Hi)
dB
64
66
67
61
66
Dimensions 
4)
H x W x D
mm
540 x 780 x 289
540 x 780 x 289
540 x 780 x 289
695 x 875 x 320
795 x 875 x 320
Net weight
kg
23
26
27
46
67
Piping connections
Liquid / Gas pipe
inch (mm)
1/4 (6.35) / 3/8 (9.52) 
1/4 (6.35) / 3/8 (9.52) 
1/4 (6.35) / 1/2 (12.70)
1/4 (6.35) / 1/2 (12.70)
1/4 (6.35) / 5/8 (15.88)
Refrigerant Loading
R410A
kg
0.77
0.86
0.92
1.22
1.8
Elevation difference (in/out) 
5)
Max
m
10
10
10
15
20
Piping length
Min / Max
m
3 / 15
3 / 15
3 / 15
3 / 20
3 / 30
Precharge length
Max
m
7
7
7
7.5
10
Additional charge
g/m
20
20
20
20
30
Operating range
Cooling Min / Max
°C
-10 / +43
-10 / +43
-10 / +43
-10 / +43
-10 / +43
Heating Min / Max
°C
-15 / +24
-15 / +24
-15 / +24
-15 / +24
-15 / +24
Rating Conditions: Cooling Indoor 27 °C DB / 19 °C WB. Cooling Outdoor 35 °C DB / 24 °C WB. Heating Indoor 20 °C DB. Heating Outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb)
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC. 2) The annual consumption is calculated by multiplying the input power at 230 V by an avarage of 500 hours per year in cooling mode. 3) The Sound pressure level of the units shows 
the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 4) Add 70 mm for piping port. 5) When installing the outdoor unit at a higher position 
than the indoor unit.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.doc.panasonic.de
5 year
compressor
warranty
42