Panasonic KIT-RE12-PKE User Manual

Page of 72
Down to
-15 ºC
 in
cooling mode
OUTDOOR
TEMPERATURE
Down to
-15 ºC
 in
heating mode
OUTDOOR
TEMPERATURE
Complete line-up with high efficiency even at -15 °C
This wall-mounted air conditioner is especially designed for professional applications such as
computer rooms where cooling inside the room is necessary even when the outside temperature
is low. Furthermore this air conditioner has an automatic changeover system, in order to maintain
the inside temperature even when sharp outside temperature changes occur.
WALL MOUNTED 
PROFESSIONAL
INVERTER -15 °C
ON COOLING MODE
KIT
KIT-E9-PKEA
KIT-E12-PKEA
KIT-E15-PKEA
KIT-E18-PKEA
Indoor
CS-E9PKEA
CS-E12PKEA
CS-E15PKEA
CS-E18PKEA
Outdoor
CU-E9PKEA
CU-E12PKEA
CU-E15PKEA
CU-E18PKEA
Cooling capacity
Nominal (Min - Max)
kW
2.50 (0.85-3.00)
3.50 (0.85-4.00)
4.20 (0.98-5.00)
5.00 (0.98-6.00)
Nominal (Min - Max)
kCal/h
2,150 (730-2,580)
3,010 (730-3,440)
3,610 (840-4,300)
4,300 (840-5,160)
EER 
1)
Nominal (Min - Max)
Energy Saving
4.85 (4.23-5.00) 
A
4.02 (3.57-5.00) 
A
3.50 (3.50-3.16) 
A
3.47 (3.50-3.02) 
A
SEER
Nominal
Energy Saving
7.1 
A++
6.7 
A++
6.3 
A++
6.9 
A++
P Design at -10 °C
kW
2.5
3.5
4.2
5.0
Power input Cooling
Nominal (Min - Max)
kW
0.515 (0.17-0.71)
0.87 (0.17-1.12)
1.20 (0.28-1.58)
1.44 (0.28-1.99)
Annual Energy Consumption (cooling)
kWh
123
183
233
254
Heating capacity
Nominal (Min - Max)
kW
3.40 (0.85-5.40)
4.00 (0.85-6.60)
5.40 (0.98-7.10)
5.80 (0.98-8.00)
Nominal (Min - Max)
kCal/h
2,920 (730-4,640)
3,440 (730-5,680)
4,640 (840-6,110)
4,990 (840-6,880)
Heating capacity at -7°C
Nominal
kW
3.91
4.78
5.14
5.80
COP 
1)
Nominal (Min - Max)
Energy Saving
4.86 (4.12-5.15) 
A
4.35 (3.63-5.15) 
A
3.75 (2.88-3.24) 
A
3.82 (2.88-3.11) 
A
SCOP
Nominal
Energy Saving
4.4 
A+
4.1 
A+
3.9 
A
4.2 
A+
P Design at -10 °C
kW
2.8
3.6
3.6
4.4
Power input Heating
Nominal (Min - Max)
kW
0.7 (0.165-1.31)
0.92 (0.165-1.82)
1.44 (0.34-2.19)
1.52 (0.340-2.57)
Annual Energy Consumption (heating)
kWh
891
1229
1292
1467
Indoor Unit
Power source
V
230
230
230
230
Recommended Fuse
A
Recommended power cable section
mm
Connection indoor / outdoor
mm
4 x 1.5
4 x 1.5
4 x 1.5
4 x 2.5
Current (Nominal) 
Cooling / Heating
A
2.5 / 3.3
4.0 / 4.2
5.4 / 6.5
6.4 / 6.8
Max. Current
A
7.8
8.4
9.6
11.3
Air Volume
Cooling / Heating
m³/h
798 / 876
816 / 882
846 / 900
1074 / 1158
Moisture removal volume
l/h
1.5
2,0
2.4
2.8
Sound pressure Level 
2)
Cooling (Hi / Lo / S-Lo) dB(A)
39 / 26 / 23
42 / 29 / 26
43 / 32 / 29
44 / 37 / 34
Heating (Hi / Lo / S-Lo) dB(A)
40 / 27 / 24
42 / 33 / 30
43 / 35 / 32
44 / 37 / 34
Sound power Level
Cooling (Hi)
dB
55
58
59
60
Heating (Hi)
dB
56
58
59
60
Dimensions 
3)
H x W x D
mm
295 x 870 x 255
295 x 870 x 255
295 x 870 x 255
295 x 1070 x 255
Net weight
Kg
10
10
10
13
Air purifier filter
Outdoor Unit
Air Volume
Cooling / Heating
m³/h
1878 / 1782
1974 / 1926
2052 / 1980
2352 / 2274
Sound pressure Level 
2)
Cooling / Heating (Hi)
dB(A)
46 / 47
48 / 50
46 / 46
47 / 47
Sound power Level
Cooling / Heating (Hi)
dB
61 / 62
63 / 65
61 / 61
61 / 61
Dimensions 3)
H x W x D
mm
622 x 824 x 299
622 x 824 x 299
695 x 875 x 320
695 x 875 x 320
Net weight
Kg
36
36
45
46
Piping connections
Liquid pipe
inch (mm)
1/4" (6.35) 
1/4" (6.35) 
1/4" (6.35)
1/4" (6.35)
Gas pipe
inch (mm)
3/8" (9.52) 
3/8" (9.52) 
1/2" (12.70)
1/2" (12.70)
Refrigerant Loading
R410A
Kg
1,100
1,100
1.060
1.240
Elevation difference (in/out) 4) Max
m
5
5
15
15
Piping length
Min / Max
m
3-15
3-15
3-15
3-20
Piping length without 
refrigerant increase
Max
m
7.5
7.5
7.5
7.5
Additional gas
g/m
20
20
20
20
Operating range
Cooling Min / Max
°C
-15 / +43
-15 / +43
-15 / +43
-15 / +43
Heating Min / Max
°C
-15 / +24
-15 / +24
-15 / +24
-15 / +24
Rating Conditions: Cooling Indoor 27 °C DB / 19 °C WB. Cooling Outdoor 35 °C DB / 24 °C WB. Heating Indoor 20 °C DB. Cooling Outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb)
This model is not suitable to use in heating mode below -5 °C with continuous operation (24 h operation).
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC. 2) The annual consumption is calculated by multiplying the input power at 230 V by an avarage of 500 hours per year in cooling mode. 3) The Sound pressure level of the units shows 
the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 4) Add 70 mm for piping port. 5) When installing the outdoor unit at a higher position 
than the indoor unit.
Specifications subject to change without notice.
A
 class
energy saving
Easy
control
by BMS
CONNECTIVITY
5 year
compressor
warranty
Internet
Control
Ready
INTERNET CONTROL
OPTIONAL
42