Konica Minolta bizhub
C364e/C284e/C224e
Specification & Installation Guide
bizhub C364e/C284e/C224e Specifications
continued
Print speed (ppm)*:
continued
Color/B&W (double sided/plain paper):
Size
Size
C364e C284e C224e
11" x 17" 18 14 14
8.5" x 14" 20 16 16
8.5" x 11"P 36 28 22
8.5" x 14" 20 16 16
8.5" x 11"P 36 28 22
8.5" x 11"L 25 20 20
5.5" x 8.5"L 36 28 22
8" x 13"L 20 16 16
*Using 1st Tray
Magnification
ratios
ratios
1.0 (full size: 1.00+_0.5% or less)
Enlarge: 121.4%, 129.4%, 154.5%, 200%
Reduce: 78.5%, 73.3%, 64.7%, 50.0%
Minimal: 93%
Stored Zoom Ratios: 3
"Minimal" zoom ratio (90% to 99.9%)
Enlarge: 121.4%, 129.4%, 154.5%, 200%
Reduce: 78.5%, 73.3%, 64.7%, 50.0%
Minimal: 93%
Stored Zoom Ratios: 3
"Minimal" zoom ratio (90% to 99.9%)
Multiple copies
1 to 9,999 sheets
Density control
Copy Density: Manual Density Adjustment
(9 Levels); Background Density: Automatic
and Manual Density Adjustments (9 levels)
(9 Levels); Background Density: Automatic
and Manual Density Adjustments (9 levels)
Power
requirements
requirements
120V, 12 A, 60 Hz
Power
consumption
consumption
1.5 kW or less
TEC Value
C364e: 2.12 kWh
C284e: 1.65 kWh
C224e: 1.25 kWh
C284e: 1.65 kWh
C224e: 1.25 kWh
Dimensions
(with control panel)
(with control panel)
24.2" (W) x 27" (D) x 31" (H)
Space requirements* 36.9" (W) x 47.8" (D) x 30.7" (H)
Memory (available
hard disk space)
Memory (available
hard disk space)
2 GB, (250 GB HDD) (std); 2 GB (opt).
Weight
Approx. 185.18 lb.
* The indicated space requirements represent the space required to pull out
the paper tray and the tray extension of the bypass tray and with the ADF open.
Duty Cycle
Up to
C364e: 125,000,
C284e: 100,000,
C224e: 80,000.
Maximum monthly copy/print volume supported under
standard vendor supplied service. Defines the upper
end of the expected customer volume for the device.
Customers should consider multiple machines if average
monthly volume approaches duty cycle on continual basis.
standard vendor supplied service. Defines the upper
end of the expected customer volume for the device.
Customers should consider multiple machines if average
monthly volume approaches duty cycle on continual basis.
Environmental Requirements
Temperature
50° F to 86° F
Humidity
15% to 85%
Noise during operation (BW/Color)
C364e: 71.6 dB/71.8 dB
C284e: 68.8 dB/69.4 dB
C224e: 66.7 dB/67.6 dB
C284e: 68.8 dB/69.4 dB
C224e: 66.7 dB/67.6 dB
Noise during feeder operation
(FS-534/FS-533)
(FS-534/FS-533)
C364e: 69.2 dB or less
C284e: 68.0 dB or less
C224e: 67.6 dB or less
C284e: 68.0 dB or less
C224e: 67.6 dB or less
Noise during standby
40.5 dB or less
Ozone emission
Color: 3.0 mg/h
Color: 1.5 mg/h
Color: 1.5 mg/h
Electrical Requirements
Line Options
Dedicated
NEMA Diagram for 5-15R
Voltage:
110 V/120
to 127 V/220
to 240 V AC
to 127 V/220
to 240 V AC
Amperage
12 A
Cycles
60 Hz
NEMA Part No:
5-15R
Cord Length
6.6 ft.
Note: The main electrical outlet must be located within 6.6 feet from the right rear
corner of the bizhub C364e/C284e/C224e main unit.
corner of the bizhub C364e/C284e/C224e main unit.