Teldat bintec WI1065n 5010590013 User Manual

Product codes
5010590013
Page of 10
bintec WI1065n
11.12.2013
Subject to technical alterations
Page 7 / 10
Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany
Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25
E-Mail: info@teldat.de - www.teldat.org
Software
Bridge: point-to-point /
point-to-multipoint
Point-to-point connection between two access points, point-to-multipoint connection between up to
eight partners access points
Bridge
Full remote configuration: Protocol with encrypted transmission. RTS/CTS threshold adjustable.
Operating channels: According to the regulatory domain. Transmit speed: Auto fallback or
selectable fixed rate.
Bridge link test
Via the link test the quality of a bridge link can be measured.
Bridge link encryption
With high security TKIP and AES possible
Client mode
Routing or bridge mode possible. In bridge mode multiple IP based end devices can be operated
simultaneously and additionally one non-IP-based end device
Buffer pool
For cushioning of peaks
WMM 802.11e QoS
Data prioritization for TOS data, 802.11e/WMM
WMM Power Save (U-APSD)
Support of active WLAN clients, which support 802.11e power save
Internet dialup
PPPoE, PPTP
Load balancing
Session-round-robin, load-dependent bandwidth
BLD
Broken Link Detection (BLD) per SSID possible.
NTP
NTP client, NTP server, manually
DNS
DNS client, DNS server, DNS relay
DHCP
DHCP client, DHCP server, DHPC relay
Maintenance
Configuration a. maintenance:
Device configuration via
Telnet, SSH, HTTP, HTTPS, SNMP
Configuration a. maintenance:
SNMP
SNMP (v1, v2, v3), USM model, VACM views, SNMP traps (v1, v2, v3) configurable, SNMP IP access
list configurable
Configuration a. maintenance:
SNMP configuration
Complete management with MIB-II, MIB 802.11, enterprise MIB
Configuration a. maintenance:
SSH Login
Supports SSH V1.5 and SSH V2.0, for secure connections of terminal applications
Configuration a. maintenance:
HTTP/HTTPS
Web-based configuration (FCI). The user interface is identical with almost all bintec elmeg
products.
Configuration a. maintenance:
Secure configuration
SSH available, HTTPS, Telnet protected against 'bruce force attacks'
Configuration a. maintenance:
Configuration export and import
Load and save of configurations; save configuration optionally encrypted; optional, automatic
controlled via scheduler
Configuration a. maintenance:
On the fly configuration
No restart is required after the configuration has been changed.
Configuration a. maintenance:
Software update
Software updates free of charge; loadable via file, HTTP or via direct access to the bintec elmeg
server; optional, automatic controlled via scheduler
External reporting: Syslog
Syslog client, with different levels of messaging.