Bosch 730 Hybrid HD 500GB DHR-730-08B050 User Manual

Product codes
DHR-730-08B050
Page of 8
1
Installation and operation manual
1
Divar 700 Series Archive Player operation manual
Technical Specifications
Electrical
Rated Voltage and Power
Power input
100 to 240 VAC; 50/60 Hz
Power consumption
Max. 2.5 to 1.0 A (250 Watt)
835 BTU/h
Able to withstand power dips up to 100 MS,
assuring continuous operation
Video
Video standard
PAL or NTSC auto-detection
Resolution
704x576 PAL, 704x480 NTSC
Compression
H.264
Inputs
8 or 16 composite video 0.5 to 2 Vpp, 75 ohm
automatic termination
Outputs
8 or 16 composite video 1 Vpp, 75 ohm, sync
0.3 V ± 10%
Audio
Inputs
8 or 16 line in (DHR models only), mono RCA,
1 Vpp, 10 kohm
Output
2 line out, dual mono RCA, 1 Vpp, 10 kohm
Compression
MPEG-1 layer II
Sampling rate
24 kHz per channel
Monitors
MON-A
Live, playback, menus
 
VGA: analog RGB 1280x1024, 60/75 Hz
(NTSC/PAL)
 
CVBS: 1 Vpp, 75 ohm, BNC
 
Y/C
MON-B (Hybrid
models only)
Live
 
VGA: analog RGB 1024x768, 60/75 Hz
(NTSC/PAL)
 
CVBS: 1 Vpp, 75 ohm, BNC
 
Y/C
Display Modes
Monitor A
Full, full sequence, quad, multi-screen (live
and playback), event call-up (live)
Monitor B (Hybrid
models only)
Full, full sequence, quad, multi-screen, event
call-up (live)
Frame rate PAL/
NTSC
25/30 IPS per channel (real time)
Multi-screen mode 8
channels
1, 2x2, 3x3 (showing 8 channels)
Multi-screen mode
16 channels
1, 2x2, 3x3, 4x4
Zoom
1.5x, 2x, 3x, 5x
Display languages
English, Chinese (Simplified), Czech, Danish,
Dutch, Finnish, French, German, Greek,
Hungarian, Italian, Japanese, Norwegian,
Polish, Portuguese, Russian, Spanish,
Swedish, Turkish.
Alarm Handling
Inputs
Screw terminal, 8 or 16 inputs, configurable
NO/NC,
 
Max. input 40 VDC
Outputs
Screw terminal 4 relay outputs, configurable
NO/NC, max. rated 30 VAC, 40 VDC, 0.5 A,
continuous -10 VA
Remote notification
Via Control Center software
Malfunction relay
Temperature related failures, 
Voltage ratings, Disk failures
Connections
Ethernet
1 or 2 RJ45 modular jack, 8 pins shielded:
 
10/100/1000 Base-T
Biphase
Screw terminal connector (5 outputs)
 
Maximum 5 controllable cameras per Biphase
output
 
Impedance 128 ohm, max. overvoltage
protection ±40 V, max. cable length 1.5 km
(0.9 miles)
Note: LTC 8785 translator needed for fixed-speed receivers/drivers
PTZ control interface
RS485
Serial interface
RS232 output signals according to EIA/
TIA-232 F, max. input voltage ±25 V
 
2xDB-9 male connector
Intuikey keyboard
(KBD Digital or
KBD Universal)
Conforms to RS485, max. signal voltage
±12 V, power supply to keyboard 11 to
12.6 VDC at max. 400 mA
 
RJ11 modular jack 6 pins
USB
Five USB 2.0 ports
10/100/1000 Base-
T network interfaces
(max 2)
Connect with Bosch iSCSI Video Storage
Arrays
Network
Bandwidth control
0.1-100 Mbps limiter
4 | 700 Series Hybrid/Network HD Recorder