Appendix A: Integration and Usage Tips 
This appendix provides a list of useful information that is unique to the Intel
®
 Entry Server 
Chassis SC5299-E and should be kept in mind while integrating and configuring your server. 
To maintain system thermals, fixed hard drive bays must be populated in the slots in this order: 
1, 3, 5, 2, 4, and 6. 
To maintain system thermals, hot-swap hard drive bays must be populated with either a hard 
drive or drive blank. 
System fans are not hot swappable. 
The CPU air duct(s) must be used to maintain system thermals. 
The Intel
®
 Local Control Panel can only be used with systems configured with an Intel
®
 
Management Module. 
Make sure the latest system software is loaded on the server. This includes system BIOS, 
FRU/SDR, BMC firmware, and hot-swap controller firmware. The latest system software can be 
downloaded from: 
http://support.intel.com/support/motherboards/server/