Power Sub-system 
Intel
®
 Entry Server Chassis SC5299-E TPS 
  
Revision 
3.1 
Intel order number D37594-005 
10 
2.1.2 
Airflow and Temperature 
The power supply operates within all specified limits over the T
op
 temperature range. The 
average air temperature difference (
  T
ps
 ) from the inlet to the outlet of the power supply does 
not exceed 20C. All airflow passes through the power supply and not over the exterior surfaces 
of the power supply. 
Table 2. Environmental Requirements 
Item 
Description 
Min 
Specification 
Units 
T
op
 Operating 
temperature range. 
50 
  C 
T
non-op
 Non-operating 
temperature range. 
-40 
70 
  C 
Altitude 
Maximum operating altitude 
 
1500 
 
The power supply meets UL enclosure requirements for temperature rise limits. All sides of the 
power supply, with the exception of the air exhaust side, are classified as “Handle, knobs, grips, 
etc. held for short periods of time only”. 
2.1.3 
Output Cable Harness 
Listed or recognized component appliance wiring material (AVLV2), CN, rated min 105
 
C, 
300Vdc is used for all output wiring.