Intel SC5299WS User Manual

Page of 154
Power Sub-system 
Intel
®
 Entry Server Chassis SC5299-E TPS 
  
Revision 
3.1 
Intel order number D37594-005 
38 
Output 
   Step Load Size (see 
note 2) 
Load Slew Rate 
Test Capacitive Load 
+12V1 25.0A 
0.25 A/
  sec  
2200 
  F 
1,2
 
+12V2 25.0A 
0.25 A/
  sec  
2200 
  F 
1,2
 
+5VSB 0.5A 
0.25 A/
  sec  
20 
  F  
Notes: 
1. 
Step loads on each 12V output may happen simultaneously. 
2. 
The +12V should be tested with 2200 
  F evenly split between the two +12V rails. 
 
2.2.4.16 
Capactive Loading 
The power supply is stable and meets all requirements with the following capacitive loading 
ranges. 
Table 42. Capacitive Loading Conditions 
Output 
MIN 
MAX 
Units 
+3.3V 250 6,800 
  F 
+5V 400 4,700 
  F 
+12V(1, 2) 
500 each 
11,000 
  F 
-12V 1  350 
  F 
+5VSB 20  350 
  F 
 
2.2.4.17 
Closed Loop Stability 
The power supply is unconditionally stable under all line/load/transient load conditions, including 
capacitive load ranges. A minimum of 45 degrees phase margin and -10dB-gain margin is 
required. Closed-loop stability is ensured at the maximum and minimum loads as applicable. 
2.2.4.18 
Common Mode Noise 
The common mode noise on any output shall not exceed 350mV pk-pk over the frequency band 
of 10Hz to 30MHz. 
2.2.4.19 
Ripple/Noise 
The maximum allowed ripple/noise output of the power supply is defined in the following table. 
This is measured over a bandwidth of 0 Hz to 20 MHz at the power supply output connectors. A 
10
  F tantalum capacitor, in parallel with a 0.1  F ceramic capacitor, is placed at the point of 
measurement.