Power Sub-system 
Intel
®
 Entry Server Chassis SC5299-E TPS 
  
Revision 
3.1 
Intel order number D37594-005 
52 
Connector 
Upper Side 
Pin No 
Top. 
Pin No. 
Bottom 
Bottom Side 
+12V 
Return 
27 28 +12V 
Return 
+12V 
Return 
29 30 +12V 
Return 
+12V 
Return 
31 32 +12V 
Return 
+12V 
Return 
33 34 +12V 
Return 
+12V 
Return 
35 36 +12V 
Return 
5VSB 
37 38 A0 
SDA 
39 40 +12V 
Sharing 
PS_KILL 
41 42 POK 
PS_ON_CTL  43 44 -PS_Present 
FAN_TACH 
45 46 VIN_GOOD_OUT 
SCL 
47 48 -OVER_TEMP 
 
Signals that can be defined as low true or high true use the following convention: 
 
Signal# = low true 
Reserved pins are reserved for future use. 
2.3.3.2 
Grounding 
The ground of the pins of the power supply output connector provide the power return path. The 
output connector ground pins are connected to safety ground (power supply enclosure).  
A reliable protective earth ground is provided on the power supply. All secondary circuits are 
connected to protective earth ground. Resistance of the ground returns to chassis do not 
exceed 1.0 m
  . This path may be used to carry DC current. 
2.3.3.3 
Remote Sense 
No remote sense and remote sense return signal is required on the 650-W power supply. 
2.3.3.4 
Output Power/Currents 
The following table defines power and current ratings for the 650-W continuous (720-W pk) 
power supply in a 1+0 or 1+1 redundant configuration. The combined output power of both 
outputs does not exceed the rated output power. The power supply meets both static and 
dynamic voltage regulation requirements for the minimum loading conditions. Also, the power 
supply supplies the listed peak currents and power for a minimum of 10 seconds. Outputs are 
not required to be peak loaded simultaneously.