2.1.2 Inrush Current Limiting   
Maximum inrush current from power-on (with power on at any point on the AC 
sine) and including, but not limited to, three line cycles, shall be limited to a 
level below the surge rating of the input line cord, AC switch if present, bridge 
rectifier, fuse, and EMI filter components. Repetitive ON/OFF cycling of the AC 
input voltage should not damage the power supply or cause the input fuse to 
blow. 
 
2.1.3 Withstand Voltage 
The power supply is capable of withstanding a maximum 1500 VDC   
potential between the input and ground for a period of 1 second. 
2.1.4 Catastrophic Failure Protection 
If a component failure occurs, the power supply will not exhibit any of   
the following: 
1) 
Flame 
2) Excessive smoke 
3) Charred PCB 
4) Fused PCB conductor 
5) Startling noise 
6) Emission of molten material 
2.2 DC Output 
2.2.1 DC Voltage Regulation 
The DC output voltages are remain within the regulation ranges shown in Table 
2 when measured at the load end of the output connectors under all line, Load, 
and environmental conditions.   
                                      Table 2.    DC Input Line Requirements 
Output 
Range Min. 
Nom.(1)
Max. 
Unit 
+12V1DC
   
± 5% 
+11.40 
+12.00 
+12.60 
Volts 
+12V2DC
   
± 5% 
+11.40 
+12.00 
+12.60 
Volts 
+5VDC ± 
5% 
+4.75 
+5.00 
+5.25 
Volts 
+3.3VDC ± 
5% +3.14 
+3.30 
+3.47 Volts 
-12VDC ± 
10% 
-10.80 
-12.00 
-13.20 
Volts 
+5VSB ± 
5% 
+4.75 
+5.00 
+5.25 
Volts 
1) ATX +12VDC peak loading, regulation at the + 12Vdc output can go to±10%.